Comet T0213D Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 v outputs

Advertisement

Quick Links

Programmable transmitter of temperature, relative humidity
© Copyright: COMET SYSTEM, Ltd.
It is prohibited to copy and make any changes in this manual, without explicit agreement
of company COMET SYSTEM, Ltd. All rights reserved.
COMET SYSTEM, Ltd. makes constant development and improvement of their products.
Manufacturer reserves the right to make technical changes to the device without previous notice.
Misprints reserved.
Manufacturer is not responsible for damages caused by using the device in conflict with this
manual.
To damages caused by using the device in conflict with this manual cannot be provide free repairs
during the warranty period.
Read carefully instruction manual before the first device connection.
Contact address of this device's producer:
T0213 TRANSMITTER
and other derived humidity values
with 0 to 10 V outputs
Instruction Manual
COMET SYSTEM, s.r.o.
Bezrucova 2901
756 61 Roznov pod Radhostem
Czech Republic
www.cometsystem.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T0213D and is the answer not in the manual?

Questions and answers

Summary of Contents for Comet T0213D

  • Page 1 It is prohibited to copy and make any changes in this manual, without explicit agreement of company COMET SYSTEM, Ltd. All rights reserved. COMET SYSTEM, Ltd. makes constant development and improvement of their products. Manufacturer reserves the right to make technical changes to the device without previous notice.
  • Page 2: Device Setting From The Manufacturer

    Instruction manual for use of T0213 transmitter Transmitter is designed for measurement of temperature at °C or °F and relative humidity of air without aggressive ingredients with computing one of the following values: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy. Measuring temperature and relative humidity sensors are non-removable instrument parts.
  • Page 3: Typical Application Wiring

    connecting. It is necessary for warranting of protection IP65. Connect complementary female connector for T0213L transmitter in accordance with the table in Appendix A of this manual. It is recommended to use shielded twisted copper cable, maximal length 15m. The cable must be located at indoor rooms.
  • Page 4 Dimensions – T0213D Dimensions – T0213L Connection: see Appendix A IE-SNC-T0213-10...
  • Page 5: Readings On Lcd Display

    LCD Info mode Several settings of installed transmitter is possible to verify without a use of the computer. It is necessary to connect power. Unscrew the transmitter lid and shortly press button between display and interconnection terminals by means of a tool (e.g. screwdriver). Range and type of value for output 1 (Uout 1 = symbol „1“on display).
  • Page 6: Technical Parameters

    Technical parameters: Accuracy data shown are for value displayed on LCD display. For value on analog output is valid too, if selected output range is set inside measuring range. Analog outputs: Two outputs with range from 0 to 10 V with common ground Output load capability: min.
  • Page 7 Specific humidity ±2g/kg at ambient temperature T < 35°C Accuracy: Range: 0 to 550 g/kg Mixing ratio ±2g/kg at ambient temperature T < 35°C Accuracy: Range: 0 to 995 g/kg Specific enthalpy ± 3kJ/kg at ambient temperature T < 25°C Accuracy: Range: 0 to 995 kJ/kg...
  • Page 8: Optional Accessory

    Optional accessory Fixing flanges: PP90 Procedure of modification of transmitter adjustment: • Device adjustment is performed by means of the optional SP003 communication cable, connected to USB port of the PC. • It is necessary to have installed configuration program Tsensor on the PC. It is free to download at www.cometsystem.com.
  • Page 9: End Of Operation

    • Measured temperature is higher than approximately 600 °C (i.e. high non-measurable resistance of temperature sensor, probably opened circuit). • Relative humidity is higher than 100%, i.e. damaged humidity sensor, or humidity calculation of humidity is not possible (due to error during temperature measurement). •...

This manual is also suitable for:

T0213

Table of Contents