  • Page 1 Owner s Manual ’ GENERATOR EU1000i See page 12 for Initial Use Instructions 2021 Honda Motor Co., Ltd. -All Rights Reserved...
  • Page 2 The information and specifications included in this publication were in effect at the time of approval for printing. Honda Motor Co., Ltd. reserves the right, however, to discontinue or change specifications or design at any time without notice and without incurring any obligation whatsoever.
  • Page 3: Introduction

    When your generator needs scheduled maintenance, keep in mind that your Honda servicing dealer is specially trained in servicing Honda generators and is supported by the parts and service divisions of American Honda. Your Honda servicing dealer is dedicated to your satisfaction and will be pleased to answer your questions and concerns.
  • Page 4 INTRODUCTION A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important. We have provided important safety messages in this manual and on the generator. This information alerts you to potential hazards that could hurt you or others.
  • Page 5: Table Of Contents

    CONTENTS INTRODUCTION ....................1 GENERATOR SAFETY ..................6 IMPORTANT SAFETY INFORMATION................6 Operator Responsibility....................6 Carbon Monoxide Hazards..................... 7 Electric Shock Hazards ..................... 8 Fire and Burn Hazards ...................... 8 Refuel With Care......................... 9 Vehicles and Transportation Hazards................. 9 SAFETY LABEL LOCATIONS....................10 INITIAL USE INSTRUCTIONS ................
  • Page 6 CONTENTS OPERATION ..................... 34 STARTING THE ENGINE .......................34 STOPPING THE ENGINE .......................37 HOW TO RESTART WHEN STOPPED BY CO-MINDER (CO SHUT-OFF SYSTEM) ..............................39 AC OPERATION ........................40 AC Applications ........................42 AC PARALLEL OPERATION ....................43 AC Parallel Operation Applications................45 ® ECO THROTTLE SYSTEM....................48 STANDBY POWER........................49 Connections to a Building’s Electrical System............49...
  • Page 7 CARBURETOR MODIFICATION FOR HIGH ALTITUDE OPERATION.......70 EMISSION CONTROL SYSTEM INFORMATION.............71 Air Index ...........................73 SPECIFICATIONS ........................74 WIRING DIAGRAM.........................76 CONSUMER INFORMATION................77 DEALER LOCATOR INFORMATION ..................77 Honda PUBLICATIONS......................77 CUSTOMER SERVICE INFORMATION ................78 Distributor’s Limited Warranty..................79 Emission Control System Warranty................84 REGISTRATION ........................89 Please Register Your Generator..................89 INDEX......................90...
  • Page 8: Generator Safety

    GENERATOR SAFETY IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all instructions in this manual and on the generator.
  • Page 9: Carbon Monoxide Hazards

    GENERATOR SAFETY Carbon Monoxide Hazards A generator's exhaust contains toxic carbon monoxide, which you cannot see or smell. Breathing carbon monoxide can KILL YOU IN MINUTES. To avoid carbon monoxide poisoning, follow these instructions when operating a generator: • Only run a generator OUTSIDE, far away from windows, doors, and vents with engine exhaust directed away from occupied structures.
  • Page 10: Electric Shock Hazards

    • Do not connect to a building’s electrical system unless an isolation switch has been installed by a qualified electrician. • For parallel operation, use only a Honda approved parallel cable (optional equipment) when connecting one EU1000i to another EU1000i generator.
  • Page 11: Refuel With Care

    GENERATOR SAFETY Refuel With Care Gasoline is highly flammable, and gasoline vapor can explode. • Do not refuel during operation. • Allow the engine to cool if it has been in operation. • Refuel only outdoors in a well-ventilated area and on a level surface. •...
  • Page 12: Safety Label Locations

    GENERATOR SAFETY SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your servicing dealer for a replacement.
  • Page 13 GENERATOR SAFETY...
  • Page 14: Initial Use Instructions

    INITIAL USE INSTRUCTIONS ENGINE OIL The generator is shipped WITHOUT OIL in the engine. 1. Place the generator on a level surface. 2. Loosen the maintenance cover screw and remove the maintenance cover. MAINTENANCE COVER SCREW MAINTENANCE COVER 3. With the generator in a level position, remove the oil filler cap by turning it counterclockwise.
  • Page 15: Engine Oil Recommendations

    AMBIENT TEMPERATURE The SAE oil viscosity and service category are in the API label on the oil container. Honda recommends that you use API service category SJ or later (or equivalent) oil.
  • Page 16: Fuel

    INITIAL USE INSTRUCTIONS FUEL Add fuel to the generator in a well-ventilated area. Fuel only outdoors. Keep gasoline away from appliance, such as pilot lights, barbecues, electric appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes environmental damage.
  • Page 17 INITIAL USE INSTRUCTIONS 1. Remove the fuel filler cap. FUEL FILLER CAP 2. Fuel carefully to avoid spilling fuel. Do not fill the fuel tank above the upper level mark (red) on the fuel strainer. UPPER LIMIT MARK (RED) FUEL STRAINER Fuel can damage paint and plastic.
  • Page 18 INITIAL USE INSTRUCTIONS 3. After refueling, tighten the fuel filler cap securely. Keep the fuel filler cap vent lever OFF for storage or transport, and ON to run the generator. FUEL FILLER CAP VENT LEVER FUEL FILLER CAP Move the generator at least 10 feet (3 meters) away from the fueling source and site before starting the engine.
  • Page 19: Fuel Recommendations

    INITIAL USE INSTRUCTIONS FUEL RECOMMENDATIONS This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher. Never use gasoline that is stale, contaminated, or mixed with oil. Avoid getting dirt or water in the fuel tank. You may use regular unleaded gasoline containing no more than 10% ethanol (E10) or 5% methanol by volume.
  • Page 20: Controls & Features

    CONTROLS & FEATURES COMPONENT & CONTROL LOCATIONS Use the illustrations on these pages to locate and identify the most frequently used controls. AC RECEPTACLES ECO THROTTLE SWITCH GROUND TERMINAL CO-MINDER PARALLEL OPERATION OUTLETS OIL ALERT/CHECK INDICATOR OVERLOAD ALARM INDICATOR OUTPUT INDICATOR FUEL FILLER CAP VENT LEVER CHOKE LEVER FUEL FILLER CAP...
  • Page 21 CONTROLS & FEATURES SPARK PLUG MAINTENANCE COVER SPARK PLUG MUFFLER...
  • Page 22: Controls

    CONTROLS & FEATURES CONTROLS Engine Switch ENGINE SWITCH The engine switch controls the ignition system and the fuel valve. OFF – Stops the engine and closes the fuel valve. ON – Running position; opens the fuel valve and allows the engine to be started.
  • Page 23: Fuel Filler Cap Vent Lever

    CONTROLS & FEATURES Fuel Filler Cap Vent Lever The fuel filler cap is provided with a vent lever to seal the fuel tank. The fuel filler cap vent lever must be in the ON position for the engine to run. When the engine is not in use, leave the fuel filler cap vent lever in the OFF position to reduce the possibility of fuel leakage.
  • Page 24: Eco Throttle Switch

    CONTROLS & FEATURES Eco Throttle® Switch The Eco Throttle® system automatically reduces engine speed when loads are turned off or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load. If high electrical loads are connected simultaneously, turn the Eco Throttle switch to the OFF position to reduce voltage changes.
  • Page 25: Co-Minder (Co Shut-Off System)

    CONTROLS & FEATURES CO-MINDER (CO Shut-off System) CO-MINDER is a system that automatically stops the engine before the surrounding carbon monoxide concentration exceeds a certain level. If the CO-MINDER detects a high carbon monoxide concentration, the engine will stop and the CO ALARM indicator will flash for about five minutes. Continuously using the generator in areas with high concentrations of carbon monoxide can cause serious health hazards due to carbon monoxide poisoning (see page 7).
  • Page 26 • The FAULT/CO SENSOR LIFE indicator indicates the estimated life left in the CO- MINDER. • The generator stopping period and storage period are also included in the useful lifespan of the CO-MINDER. • Contact an authorized Honda Power Equipment dealer for CO-MINDER replacement.
  • Page 27: Parallel Operation Outlets

    Parallel Operation Outlets These outlets are used for connecting two EU1000i generators for parallel operation (see page 43). A Honda-approved parallel operation cable (optional equipment) is required for parallel operation. This cable can be purchased from an authorized Honda Power Equipment dealer.
  • Page 28: Features

    CONTROLS & FEATURES FEATURES Output Indicator The output indicator (green) is illuminated when the generator is operating normally. It indicates that the generator is producing electrical power at the receptacles. In addition, the output indicator has a simplified hour meter function. When you start the engine, the indicator blinks according to the generator’s cumulative operating hours as follows: •...
  • Page 29: Oil Alert®/Check Indicator

    CONTROLS & FEATURES Oil Alert®/Check Indicator The Oil Alert® system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert/Check indicator (red) comes ON and the Oil Alert system automatically will stop the engine (the engine switch will remain in the ON position).
  • Page 30: Before Operation

    BEFORE OPERATION ARE YOU READY TO GET STARTED? Your safety is your responsibility. A little time spent in preparation will significantly reduce your risk of injury. Knowledge Read and understand this manual. Know what the controls do and how to operate them.
  • Page 31: Check The Engine

    BEFORE OPERATION To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building walls and other equipment during operation. Do not place flammable objects close to the engine. Before beginning your pre-operation checks, be sure the generator is on a level and firm surface and the engine switch is in the OFF position.
  • Page 32: Engine Oil Level Check

    BEFORE OPERATION ENGINE OIL LEVEL CHECK Check the engine oil level with the generator on a level surface and the engine stopped. 1. Loosen the maintenance cover screw and remove the maintenance cover. MAINTENANCE COVER SCREW MAINTENANCE COVER 2. Remove the oil filler cap by turning it counterclockwise. Wipe the dipstick clean.
  • Page 33 BEFORE OPERATION 6. Reinstall the maintenance cover and tighten the maintenance cover screw securely. OIL FILLER CAP DIPSTICK UPPER LIMIT (The oil exists to the oil filler neck.) LOWER LIMIT (The oil is attached only to the lower end of the dipstick.) OIL FILLER NECK The Oil Alert system will automatically stop the engine before the oil level falls below safe limits.
  • Page 34: Air Filter Check

    BEFORE OPERATION AIR FILTER CHECK MAINTENANCE COVER SCREW 1. Loosen the maintenance cover screw and remove the maintenance cover. 2. Press the latch tab on the top of the air cleaner case, and remove the air cleaner cover. 3. Check the foam air filter to be sure it is clean and in good condition.
  • Page 35: Safe Operating Precautions

    BEFORE OPERATION SAFE OPERATING PRECAUTIONS Before operating the generator, review chapters "GENERATOR SAFETY" (see page 6). For your safety, do not operate the generator in an enclosed, or partly enclosed area such as a garage (even if the door is open) or near structures or vehicles. Your generator's exhaust contains poisonous carbon monoxide gas that can collect rapidly in such areas, structures, vehicles, trailers, or boats.
  • Page 36: Operation

    OPERATION STARTING THE ENGINE To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from building or trailer walls, vehicles, trailers, boats, and other equipment during operation. Do not place flammable objects close to the engine. •...
  • Page 37 OPERATION 3. Make sure the Eco Throttle switch is ECO THROTTLE SWITCH in the OFF position, or more time will be required for warm-up. 4. To start a cold engine, move the CHOKE LEVER choke lever to the CLOSED position. To restart a warm engine, leave the choke lever in the OPEN position.
  • Page 38 OPERATION 6. Pull the starter grip lightly until you feel resistance; then pull briskly in the direction of the arrow as shown. STARTER GRIP Do not allow the starter grip to snap Direction to pull back against the generator. Return it gently to prevent damage to the starter.
  • Page 39: Stopping The Engine

    OPERATION STOPPING THE ENGINE To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal conditions, use the following procedure. 1. Turn off or disconnect all appliances that are connected to the generator. 2.
  • Page 40 OPERATION 4. If two generators were connected for parallel operation, disconnect the parallel operation cable after stopping the engines if you do not wish to resume parallel operation. PARALLEL OPERATION CABLE (optional equipment)
  • Page 41: How To Restart When Stopped By Co-Minder (Co Shut-Off System)

    OPERATION HOW TO RESTART WHEN STOPPED BY CO-MINDER (CO SHUT-OFF SYSTEM) When the engine is automatically stopped by the CO-MINDER, move the generator to an area with fresh air and away from any device that may be emitting carbon monoxide, such as another generator. Press the CO-MINDER reset button and then follow the standard procedure for starting the engine.
  • Page 42: Ac Operation

    ON. This is normal if the overload alarm indicator (red) goes OFF within 4 seconds. If the overload alarm indicator (red) stays ON, consult an authorized Honda Power Equipment dealer. 1. Start the engine (see page 34) and make sure the output indicator (green) comes ON.
  • Page 43 OPERATION 2. Plug the appliance into the receptacle. 3. Turn on the appliance. If the generator is overloaded (see page 42), or if there is a short circuit in a connected appliance, the overload alarm indicator (red) will go ON. The overload alarm indicator (red) will stay ON, and after about four seconds, current to the connected appliance(s) will shut off, and the output indicator (green) will go OFF.
  • Page 44: Ac Applications

    OPERATION AC Applications Before connecting an appliance or power cord to the generator: • Make sure that it is in good working order. A faulty appliance or power cord can create a potential for electrical shock. • If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn it off immediately.
  • Page 45: Ac Parallel Operation

    ON. This is normal if the overload alarm indicator (red) goes OFF within 4 seconds. If the overload alarm indicator (red) stays ON, consult an authorized Honda Power Equipment dealer. During parallel operation, the Eco Throttle switch should be in the same position on both generators.
  • Page 46 OPERATION 3. Plug the appliance following the instruction provided with the parallel operation cable. 4. Turn on the appliance. If the generators are overloaded (see page 47), or if there is a short circuit in a connected appliance, the overload alarm indicator (red) will go ON. The overload alarm indicator (red) will stay ON, and after about four seconds, current to the connected appliance(s) will shut off, and the output indicator (green) will go OFF.
  • Page 47: Ac Parallel Operation Applications

    • Never connect different generator models. • Use only a Honda-approved parallel operation cable (optional equipment, see page 77) when connecting two EU1000i generators for parallel operation. • Never connect or remove the parallel operation cable when the generator is running.
  • Page 48 OPERATION When operating generators in parallel operation, if one generator emits exhaust toward the other, the CO-MINDER (CO Shut-off System) of the generator that is receiving the exhaust may stop the engine. Pay attention to the following for placing generators in parallel operation. •...
  • Page 49 OPERATION Most appliance motors require more than their rated wattage for startup. Make sure the electrical rating of the tool or appliance does not exceed the maximum power rating of the generator. Maximum power in parallel operation is: 2.0 kVA For continuous operation, do not exceed the rated power.
  • Page 50: Eco Throttle® System

    OPERATION ECO THROTTLE® SYSTEM With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned off, or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load.
  • Page 51: Standby Power

    OPERATION STANDBY POWER Connections to a Building’s Electrical System Connections for standby power to a building’s electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.
  • Page 52: Special Requirements

    OPERATION Special Requirements Do not lay the generator on its side when moving, storing, or operating it. Oil and fuel may leak and damage the engine or your property. There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator.
  • Page 53: Servicing Your Generator

    Remember that an authorized Honda Power Equipment dealer knows your generator best and is fully equipped to maintain and repair it. To ensure the best quality and reliability, use only new, Honda Genuine parts or their equivalents for repair and replacement.
  • Page 54: Maintenance Safety

    SERVICING YOUR GENERATOR MAINTENANCE SAFETY Some of the most important safety precautions follow. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not you should perform a given task.
  • Page 55: Maintenance Schedule

    (1) Service more frequently when used in dusty areas. (2) These items should be serviced by your servicing dealer, unless you have the proper tools and are mechanically proficient. Refer to the Honda shop manual for service procedures. See "Honda PUBLICATIONS" on page 77 for ordering information.
  • Page 56 SERVICING YOUR GENERATOR 4. Remove the oil filler cap, and drain the oil into the container by tipping the engine toward the oil filler neck. Improper disposal of engine oil can be harmful to the environment. If you change your own oil, please dispose of the used oil properly. Put it in a sealed container, and take it to a recycling center.
  • Page 57: Air Cleaner Service

    SERVICING YOUR GENERATOR AIR CLEANER SERVICE Foam Air Filter Cleaning A dirty foam air filter will restrict air flow to the carburetor, reducing engine performance. If you operate the generator in very dusty areas, clean the foam air filter more frequently than specified in the Maintenance Schedule (see page 53).
  • Page 58: Spark Plug Service

    SERVICING YOUR GENERATOR SPARK PLUG SERVICE In order to service the spark plug, you will need a spark plug wrench (commercially available). Required spark plug: LR4C-E (NGK) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. An incorrect spark plug can cause engine damage.
  • Page 59 SERVICING YOUR GENERATOR 4. Inspect the spark plug. Replace it if SIDE ELECTRODE the electrodes are worn or fouled, or if the insulator is cracked or chipped. SEALING WASHER Clean the spark plug with a wire 0.024–0.028 in brush if it is to be reused. (0.6–0.7 mm) 5.
  • Page 60: Spark Arrester Service

    SERVICING YOUR GENERATOR SPARK ARRESTER SERVICE The spark arrester must be serviced every 100 hours to keep it functioning as designed. If the engine has been running, the muffler will be very hot. Allow the muffler to cool before servicing the spark arrester. Clean the spark arrester as follows: 1.
  • Page 61 SERVICING YOUR GENERATOR 3. Use a brush to remove carbon deposits from the spark arrester screen. Be careful to avoid damaging the screen. The spark arrester must be free of breaks and tears. Replace the spark arrester if it is damaged. 4.
  • Page 62: Storage

    STORAGE STORAGE PREPARATION Proper storage preparation is essential for keeping your generator trouble-free and looking good. The following steps will help to keep rust and corrosion from impairing your generator’s function and appearance, and will make the engine easier to start when you use the generator again. Cleaning Wipe the generator with a moist cloth.
  • Page 63 Change the engine oil and lubricate the cylinder (see page 63). *Use gasoline stabilizers that are formulated to extend storage life. Follow the manufacturer’s instructions for use. Contact your authorized Honda Power Equipment dealer for stabilizer recommendations. DRAINING THE FUEL TANK AND CARBURETOR Gasoline is highly flammable and explosive.
  • Page 64 STORAGE 2. Loosen the maintenance cover screw and remove the maintenance cover (see page 30). 3. Loosen the carburetor drain screw, and drain the gasoline from the carburetor into a suitable container. 4. Remove the spark plug maintenance cover, and the spark plug cap (see page 56).
  • Page 65: Engine Oil

    STORAGE Engine Oil Change the engine oil (see page 53). Engine Cylinder 1. Remove the spark plug (see page 56), and pour approximately one teaspoon (5 cc) of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, and then reinstall the spark plug. 2.
  • Page 66: Storage Precautions

    STORAGE STORAGE PRECAUTIONS If your generator will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition. Select a well-ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer. Also avoid any area with a spark-producing electric motor, or where power tools are operated.
  • Page 67: Transporting

    TRANSPORTING An engine that has been running will remain very hot for a period of time. A hot engine and exhaust system can burn you and ignite some material. If the generator has been used, allow it to cool for at least 15 minutes before loading the generator on the transport vehicle.
  • Page 68: Taking Care Of Unexpected Problems

    Spark plug wet with fuel (flooded Dry and reinstall spark plug. engine). Fuel strainer restricted, carburetor Take the generator to an authorized Honda malfunction, ignition Power Equipment dealer, or refer to the malfunction, valves stuck, etc. shop manual.
  • Page 69: Engine Lacks Power

    Refuel with fresh gasoline (see page 15). Fuel strainer restricted, carburetor Take the generator to an authorized malfunction, ignition malfunction, Honda Power Equipment dealer, or valves stuck, etc. refer to the shop manual. NO POWER AT THE AC RECEPTACLES Possible Cause...
  • Page 70: Engine Automatically Stop And The Co Alarm Indicator Flashing

    CO-MINDER malfunction. Consult an authorized Honda Power Equipment dealer. CO sensor may have reached the end Consult an authorized Honda Power of its useful lifespan (see page 24). Equipment dealer. FAULT/CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING THE...
  • Page 71: Technical Information

    TECHNICAL INFORMATION SERIAL NUMBER LOCATION FRAME SERIAL NUMBER Record the frame serial number and date purchased in the spaces below. You will need this information when ordering parts and when making technical or warranty inquiries. Frame serial number: Date purchased:...
  • Page 72: Carburetor Modification For High Altitude Operation

    High altitude performance can be improved by specific modifications to the carburetor. If you always operate your generator at altitudes above 2,000 feet (610 meters), have your authorized Honda servicing dealer perform this carburetor modification. This engine, when operated at high altitude with the carburetor modifications for high altitude use, will meet each emission standard throughout its useful life.
  • Page 73: Emission Control System Information

    Carbon monoxide does not react in the same way, but it is toxic. Honda utilizes appropriate air/fuel ratios and other emissions control systems to reduce the emissions of carbon monoxide, oxides of nitrogen, and hydrocarbons.
  • Page 74 Honda recommends that you retain all receipts covering maintenance on your power equipment engine, but Honda cannot deny warranty coverage solely for the lack of receipts or for your failure to ensure that all scheduled maintenance has been completed.
  • Page 75: Air Index

    TECHNICAL INFORMATION Air Index (Models certified for sale in California) An Air Index Information label is applied to engines certified to an emission durability time period in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines.
  • Page 76: Specifications

    TECHNICAL INFORMATION SPECIFICATIONS Dimensions Model EU1000iT1 Description code EAAT Length 17.8 in (451 mm) Width 9.5 in (242 mm) Height 14.9 in (379 mm) Dry mass [weight] 29.5 lbs (13.4 kg) Engine Model GXH50T Engine type 4-stroke, overhead valve, single cylinder Displacement 3.01 cu-in (49.4 cm...
  • Page 77 Refer to page 56. (0.6 – 0.7 mm) Valve clearance (cold) IN: 0.08 ± 0.02 mm See your authorized EX: 0.11 ± 0.02 mm Honda Power Equipment dealer. Other specifications No other adjustments needed. Specifications are subject to change without notice.
  • Page 78: Wiring Diagram

    TECHNICAL INFORMATION WIRING DIAGRAM...
  • Page 79: Consumer Information

    Parts Catalog This manual provides complete, illustrated parts lists for your generator. Visit peparts.honda.com for free online access to the parts catalog. It is also available for purchase in paper form through your Honda dealer. Accessories Catalog Your authorized Honda Power Equipment dealer offers a wide selection of accessories (optional equipment) to make your generator even more useful.
  • Page 80: Customer Service Information

    The Service Manager or General Manager can help. Almost all problems are solved in this way. If you are dissatisfied with the decision made by the dealership’s management, contact the Honda Power Equipment Customer Relations Office. You can write American Honda Motor Co., Inc. Power Equipment Division...
  • Page 81: Distributor's Limited Warranty

    What American Honda will Repair or Replace Under Warranty: American Honda will repair or replace, at its option, any part that is proven to be defective in material or workmanship under normal use during the applicable warranty time period. Warranty repairs and replacements will be made without charge for parts or labor.
  • Page 82 You must, at your expense, take the Honda Power Equipment product, accessory, replacement part, apparel, or the power equipment on which the accessory or replacement part is installed, and proof of purchase to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S. Virgin Islands who is authorized to sell and/or service that product, during the dealer’s...
  • Page 83 Disclaimer of Consequential Damage and Limitation of Implied Warranties: American Honda disclaims any responsibility for loss of time or use of the product, transportation, commercial loss, or any other incidental or consequential damage. Any implied warranties are limited to the duration of this written limited warranty.
  • Page 84 To Qualify for This Warranty: 1. The parts, accessories, or apparel must be purchased from American Honda or a dealer authorized by American Honda to sell those products in the United States, Puerto Rico, and the U.S. Virgin Islands. Parts and accessories must be purchased for installation on original Honda equipment or engines to be eligible for warranty coverage.
  • Page 85 CONSUMER INFORMATION To Obtain Warranty Service: You must, at your expense, take the Honda Power Equipment part, accessory, or apparel, or the Honda Power Equipment on which the accessory or part is installed, and proof of purchase to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S.
  • Page 86: Emission Control System Warranty

    MANUFACTURER'S WARRANTY COVERAGE: The exhaust and evaporative emissions control system on your Honda power equipment engine is warranted for two years. If any emissions-related part on your Honda power equipment engine is defective, the part will be repaired or replaced by Honda.
  • Page 87 • As the power equipment engine owner, you should however be aware that Honda may deny you warranty coverage if your power equipment engine or a part has failed due to abuse, neglect, improper maintenance, or unapproved modifications.
  • Page 88 (including durability) could result in denial of coverage. If such a non-Honda replacement part is used in the repair or maintenance of your engine, and an authorized Honda dealer determines it is defective or causes a failure of a warranted part, your claim for repair of your engine may be denied.
  • Page 89 Honda Power Equipment dealer who is authorized by Honda to sell and service that Honda product during their normal business hours. Claims for repair or adjustment found to be caused solely by defects in material or workmanship will not be denied because the engine was not properly maintained and used.
  • Page 90 DISCLAIMER OF CONSEQUENTIAL DAMAGE AND LIMITATION OF IMPLIED WARRANTIES: American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any responsibility for incidental or consequential damages such as loss of time or the use of the power equipment, or any commercial loss due to the failure of the equipment;...
  • Page 91: Registration

    Please Register Your Generator If your dealer did not collect registration information from you, please take a few minutes and register your purchase with Honda. This allows us to contact you with any important updates regarding your generator. Please note registration is not required to obtain warranty service.
  • Page 92: Index

    INDEX AC Appliance and Power Cord..................29 AC Applications ........................42 AC OPERATION ........................40 AC Parallel Operation Applications................45 AC PARALLEL OPERATION ....................43 AIR CLEANER SERVICE ......................55 AIR FILTER CHECK ........................ 32 Air Index ..........................73 ARE YOU READY TO GET STARTED? ................28 BEFORE OPERATION ......................
  • Page 93 Fuel Filler Cap Vent Lever ....................21 FUEL RECOMMENDATIONS....................17 FUEL........................... 14, 60 GENERATOR SAFETY ......................6 Ground Terminal........................27 Honda PUBLICATIONS......................77 HOW TO RESTART WHEN STOPPED BY CO-MINDER (CO SHUT-OFF SYSTEM) ............................... 39 IMPORTANT SAFETY INFORMATION................6 INITIAL USE INSTRUCTIONS....................12 INTRODUCTION ........................
  • Page 94 INDEX MAINTENANCE SCHEDULE....................53 NO POWER AT THE AC RECEPTACLES ................67 ® Oil Alert /Check Indicator ....................27 OPERATION ..........................34 Operator Responsibility....................... 6 Overload Alarm (Indicator)....................26 Output Indicator ........................26 Parallel Operation Outlets ....................25 Please Register Your Generator..................89 QUICK REFERENCE INFORMATION ..........
  • Page 95 INDEX System Ground ........................49 TAKING CARE OF UNEXPECTED PROBLEMS............... 66 TECHNICAL INFORMATION ....................69 THE IMPORTANCE OF MAINTENANCE................51 TRANSPORTING ........................65 Vehicles and Transportation Hazards................9 WIRING DIAGRAM........................ 76...
  • Page 96 MEMO...
  • Page 97 MEMO...
  • Page 98 MEMO...
  • Page 99: Quick Reference Information

    QUICK REFERENCE INFORMATION Fuel Type Regular unleaded gasoline with an ethanol content of no more than 10% and a pump octane rating of 86 or higher Engine Oil Type SAE 10W-30, API SJ or later (or equivalent), for general use (see page 13) Maximum oil capacity: 8 oz (0.25 L) Spark Plug...
  • Page 100 EU1000i 31Z40611 AH 英 00X31-Z40-6110 Printed in Thailand...