Storage Of New Turbochargers And Spare Parts - ABB A130-M65 Operation Manual

Hide thumbs Also See for A130-M65:
Table of Contents

Advertisement

Operation Manual / 1 Introduction
1
Introduction
1.3

Storage of new turbochargers and spare parts

Storage of new turbochargers and spare parts up to 6 months
New turbochargers and spare parts from ABB Turbo Systems can be stored in sealed
packaging without additional mothballing measures for up to 6 months from the date of
delivery (marked by the VCI label on the package).
Figure 2: Volatile Corrosion Inhibitor (VCI)
Only dry rooms in which the relative humidity is between 40...70 % and no condensation can
form are suitable for storage.
Storage of new turbochargers and spare parts for more than 6 months
Protection of health when handling VCIs
VCI products are not hazardous in the sense of the Hazardous Substances
Ordinance. Nevertheless, the following points are to be observed when
WARNING
handling VCIs:
Observe specifications in the safety data sheet
Ensure good room ventilation.
Do not eat, drink or keep food at the workplace while working with VCIs.
Clean hands and face after working with VCIs.
For further information refer to www.branopac.com.
Wear safety gloves against mechanical risks.
The following mothballing measures are required every 6 months:
Open the package.
Remove the VCI corrosion protection emitter from the package and replace it with a new,
identical VCI corrosion protection emitter. New VCI corrosion protection emitters can be
obtained at www.branopac.com.
Dispose of the old VCI corrosion protection emitter in an environmentally compatible
manner, professionally and in accordance with local regulations.
Seal the package. The better the external seal is designed, the more permanent the
protection.
© Copyright 2015 ABB. All rights reserved.
HZTL4005_EN
Page 6 / 8
Revision D
September 2015

Advertisement

Table of Contents
loading

Table of Contents