Inbound Verification - Cal Amp LMU-2 30 Series Hardware And Installation Manual

Table of Contents

Advertisement

LMU-2x20™ Hardware and Installation Guide

4.5.3 Inbound Verification

The last item to verify is that the LMU-2x30™ is sending data to the correct server. In
general, this is a two-step process that will need the aid of an observer on the back end. That
is, a technician will have to be logged in so they can monitor data coming into the backend
mapping/vehicle management application.
First, verify that the LMU-2x30™ is using the correct Inbound IP address by using:
AT$APP INBOUND?
The response should be similar to:
INBOUND LMD
INBOUND 0 ADDR ddd.ddd.ddd.ddd:ppppp *
INBOUND 0 URL
INBOUND 1 ADDR 0.0.0.0:20500
INBOUND 1 URL
INBOUND 2 ADDR 0.0.0.0:20500
INBOUND 3 ADDR 0.0.0.0:20500
The installer will need to verify with a backend technician that the, URL
(myURL.myCompany.com ), IP address (ddd.ddd.ddd.ddd) and port (<ppppp>) are correct.
The second step is to verify that the LMU-2x30™ is sending data. The best way to do this is
to force the LMU-2x30™ to send in an unacknowledged Event Report (i.e., its current GPS
location) with the following command:
AT$APP PEG SUNRPT 255
The LMU-2x30™ will respond with: OK
The backend monitor must then be contacted to confirm that they received an Event Report
with Event Code 255.
Assuming that all three sections have passed, the installation can be considered to be
complete.
V1.0.10
Copyright ©Calamp Wireless Networks Inc 2010
myURL.myCompany.com
- 49 -
December 12, 2010
CalAmp Proprietary & Confidential