Quick Start - General Config - Cal Amp LMU-2 30 Series Hardware And Installation Manual

Table of Contents

Advertisement

LMU-2x20™ Hardware and Installation Guide

3.6 Quick Start - General Config

All LMU-2x30s™ must go through a common step during the configuration and
provisioning process. Specifically, this is pointing the LMU to the LM Direct™ server, either
via IP or a URL
This configuration process is accomplished via a series of AT Commands.
1. Power up the LMU-2x30™
2. Plug the serial cable into your laptop
3. Open a terminal session to the LMU-2x30™
4. Enter the address of the LM Direct™ server.
AT$APP PARAM 768,0,ddd.ddd.ddd.ddd
AT$APP PARAM 769,0,ppppp
where ddd.ddd.ddd.ddd is the publicly addressable IPV4 address of the server and
ppppp is the UDP port number
The LMU-2x30™ will respond with: OK
5. Alternatively if a URL has been set up it may be programmed with:
AT$APP PARAM 2319,0, "myURL.MyCompany.Com"
Where "myURL.MyCompany.com" is the URL assigned to the server, the LMU-
2x30™ will respond with: OK
Note that if you are not using a URL, this field must be cleared using:
AT$APP PARAM 2319,0, ""
6. Verify your settings by using:
AT$APP INBOUND?
V1.0.10
Copyright ©Calamp Wireless Networks Inc 2010
CalAmp Proprietary & Confidential
- 24 -
December 12, 2010

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lmu-2630/12630mb

Table of Contents