ADVANCED
PRODUCT SETTINGS
(CONT.)
5-2
E-LOG
(ERROR CODE LOG)
July 2014
8.
Press ▼ button until "FULL HT" shows in the display along with
the full heat value in seconds, which means the heat is on as soon as
a timer button is pressed, for the programmed length of time. Press
the product buttons
value of 0 to 90 seconds.
9.
Press ▼ button until "PC FACTOR" shows in the display along
with the proportional temperature, which helps to keep the oil from
over-shooting the setpoint temperature. Press the product buttons
Use ▲ button to go back to previous menu items.
Press X button when finished with the current product, to return to the
PRODUCT SELECTN step.
Press X button a second time to exit PROD COMP mode.
1.
Press and hold
display, followed by ENTER CODE.
2.
Enter code 1, 2, 3, 4 (first 4 product buttons). "PROD" and
"COMP" show in the displays.
3.
Press ▼ button and "E-LOG" shows in the display.
4.
Press right
button and "A" plus the present date & time flashes on
the display, along with *NOW*".
5.
Press ▼ and if an error was recorded, "B" and the date, time, and
error code information shows in display. This is the latest error code
that the controls recorded.
6.
Press ▼ and the next latest error code information can be seen. Up
to 10 error codes (B to K) can be stored in the E-Log Section.
Press and hold the right
41
to change this value of 0 to 50 degrees.
and
buttons until LEVEL - 2 shows in the
button to view a brief description of the error.