Rear Exit Horizontal Termination - Continental Fireplaces Builder 42 Series Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

venting requirements
EN
2.8

rear exit horizontal termination

Simple venting configuration
(only two 90° elbows)
For vent configurations requiring more than two 90° elbows, the following formulas apply:
Formula 1: H
< V
T
T
Formula 2: H
+ V
< 40 feet (12.2m)
T
T
Example:
= 9 FT (2.7m)
V
1
= 6 FT (1.8m)
V
2
= V
= 9FT (2.7m) + 6FT (1.8m) = 15FT (4.6m)
V
+ V
T
1
2
= 3 FT (0.9m)
H
1
= 2 FT (0.6m)
H
2
= 1.5 FT (0.5m)
H
3
= H
= 3FT (0.9m) + 2FT (0.6m) + 1.5FT (0.5m) = 6.5FT (2m)
H
+ H
+ H
R
1
2
3
= .03 (four 90° elbows - 90°) = .03 (360° - 90°) = 8.1 FT (2.5m)
H
O
= H
= 6.5FT (2m) + 8.1FT (2.5m) = 14.6FT (4.5m)
H
+ H
T
R
O
= 14.6FT (4.5m) + 15FT (4.6m) = 29.6 FT (9m)
H
+ V
T
T
Formula 1:
H
< V
T
14.6 FT (4.5m) < 15 FT (4.6m)
Formula 2:
H
+ V
T
29.6 FT (9m) < 40 FT (12.2m)
Since both formulas are met, this vent configuration is acceptable.
18
W415-3096 / C / 05.03.22
T
< 40 FT (12.2m)
T
(H
) < (V
)
T
T
See graph to determine the required vertical rise V
horizontal run H
40 (12.2)
38.3 (11.7)
REQUIRED
30 (9.1)
VERTICAL
RISE IN FEET
20 (6.1)
(METERS) V
T
10 (3.1)
1.6 (0.5)
0
2.5
(0.8)
1.6
(0.5)
HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS) H
The shaded area within the lines represents acceptable values for H
for the required
T
.
T
5
7.5
10
12.5
15
(1.5)
(2.3)
(3.1)
(3.8)
(4.6)
and H
T
90°
H
3
V
2
90°
H
2
90°
V
1
H
1
90°
13.2
17.5
20
(5.3)
(6.1)
T
T