Continental Fireplaces CDIZC - N Installation And Operation Instructions Manual
Continental Fireplaces CDIZC - N Installation And Operation Instructions Manual

Continental Fireplaces CDIZC - N Installation And Operation Instructions Manual

Gas-fired direct vent insert

Advertisement

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
INSTALLATION AND OPERATION INSTRUCTIONS FOR:
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapours and liquids in the vicinity
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
Installation and service must be performed by a qualified installer, service
R-2000
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
GAS-FIRED DIRECT VENT INSERT
VENTED GAS FIREPLACE HEATER
NATURAL GAS MODELS
PROPANE GAS MODELS
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS
FOR YOUR SAFETY
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
agency or the gas supplier.
www.continentalfireplaces.com • ask@continentalfire.com
CDIZC - N
CDIZC - P
• Immediately call your gas supplier
from a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
1
W415-0224 / D / 01.15.04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CDIZC - N and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Continental Fireplaces CDIZC - N

  • Page 1 R-2000 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www.continentalfireplaces.com • ask@continentalfire.com VENTED GAS FIREPLACE HEATER CDIZC - N NATURAL GAS MODELS CDIZC - P PROPANE GAS MODELS CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS FOR YOUR SAFETY of this or any other appliance.
  • Page 2: Table Of Contents

    TABLE of CONTENTS Pg 2-4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts INSTALLATION Insert Vent Connection Chimney Connection Wall Switch / Thermostat Gas Pipe Installation FINISHING Trim Extrusion Installation Log Placement Door Installation Mantle Clearances Logo Placement PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE •...
  • Page 3: Warranty

    This warranty defines the obligations and liability of WOLF STEEL Ltd. with respect to the CONTINENTAL gas fireplace and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.
  • Page 4: General Instructions

    The glass is 3/16" ceramic glass available from your Continental / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MATERIALS. Clean the glass after the first 10 hours of op- eration with a recommended gas fireplace glass cleaner.
  • Page 5: Installation

    Provide adequate ventilation air. Provide adequate accessibility clearance for servicing and operating the fireplace insert. Never obstruct the front opening of the fire- place insert. Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.
  • Page 6: Insert Vent Connection

    2" or 3" diameter liner for intake and one 3" diameter liner for exhaust. The minimum and maximum vent lengths are 10 and 35 feet respectively. Recommended Continental kits come in 3 lengths: While the liners must be continuous...
  • Page 7: Wall Switch / Thermostat

    WALL SWITCH / THERMOSTAT For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fireplace insert to the wall switch / millivolt ther- mostat.
  • Page 8: Log Placement

    Take the time to carefully position the glowing embers for a maximum glowing effect. Use only certified PHAZER logs available from your Continental / Wolf Steel Ltd. dealer. 1. Place the rear log (#1) onto the two log supports and against the air intake pipe.
  • Page 9: Lighting

    A 5-10 second total light-up period is satisfactory. If ignition takes longer, consult your Continental dealer/distributor. 7. Check that the door gasketing is not broken or missing. Replace if necessary.
  • Page 10: Replacement Blower

    REPLACEMENT BLOWER INSTALLATION The Napoleon gas fireplace insert comes standard with a blower, a heat sensor, variable on/off speed control and a power cord. Because the blower is thermally activated, when turned on, it will automatically start approximately 15 minutes after lighting the fireplace and will run for approxi- mately 30 minutes after the fireplace has been turned off.
  • Page 11: Adjustments

    PILOT BURNER ADJUSTMENT Remove the pilot screw cap. Adjust the pilot screw to pro- vide properly sized flame. Turn in a clockwise direction to reduce the gas flow. Replace the pilot screw cap. FIGURE 27 FIGURE 28 VENT RESTRICTION Some vent configurations may display a very active flame. If this appearance is not desirable, the vent exit may be re- stricted using the restrictor plate shown in FIGURE 6b.
  • Page 12: Replacements

    Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Continental dealer or distributor. IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED FURTHER INFORMATION CONTACT YOUR DEALER FOR WARRANTY REPLACEMENT PARTS REPLACEMENT PARTS...
  • Page 13 W415-0224 / D / 01.15.04 WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
  • Page 14: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT SYMPTOM PROBLEM Pilot will not light. No spark at pilot burner Spark gap is incorrect No gas at the pilot burner Out of propane gas. System is not correctly purged. - purge the gas line with the glass door open. Pilot goes out when the gas knob is re- Out of propane gas...
  • Page 15 SYMPTOM PROBLEM REFER TO "MAIN BURNER GOES OUT; PILOT STAYS ON" Main burner goes out; pilot goes out. Vent re-circulating Thermocouple shorting or faulty. Vent is reversing Exhaust fumes Fireplace is spilling. smelled room, headaches. Carbon is being de- Air shutter has become posited on glass, blocked logs or combustion...
  • Page 16 W415-0224 / D / 01.15.04...