Assembly Instructions
SETUP INSTRUCTIONS
Walker Mowers are shipped partially assembled to
our distribution network, and are typically assem
bled by the selling dealer. For any additional as
sembly besides the following, contact your Walker
dealer.
Tire Installation (Tractor)
●
Install the drive tires using the eight (8) mount
ing nuts supplied with the Owner's Packet of
materials. Nuts are torqued to 75 to 85 lb
·
(102 to 115 N
m).
●
Check and adjust the inflation of the tires.
The tire inflation recommendations are:
Drive
=
Tailwheel
=
Battery Service
Important Battery Service, Installation, and
Charging Tips for Electronic Fuel Injection
Engines:
●
Do not allow the battery cables to touch
opposing terminals. When connecting
battery cables attach the positive (+)
cable to positive (+) battery terminal
first, followed by negative (-) cable to
negative (-) battery terminal.
Never start the engine when the cables
●
are loose or poorly connected to the
battery terminals.
Never disconnect battery while engine
●
is running.
●
Never use a quick battery charger to
start the engine.
Never "jump start" the engine using
●
another source.
tions can damage the ECU (Electronic
Control Unit).
●
Always disconnect negative (-) battery
cable lead before charging battery, and
also unplug harness from ECU before
performing any welding on equipment.
18
15 PSI (103 kPa)
20 PSI (137 kPa)
CAUTION
Electricity fluctua-
Raise mower body up for battery access. Check the
battery for electrolyte level and charge. The electro
lyte level should be at the bottom of the vent wells
[1/4 to 1/2 in. (6 to 13 mm) above plates]. If the
specific gravity is less than 1.225, the battery needs
charging. If the battery has been shipped dry, or is
wet but needs service, refer to the following instruc
tions.
·
ft
IMPORTANT: Make sure battery is securely mount
ed in the frame. A loose battery may cause damage
to the case resulting in acid leakage and se vere
damage to the machine. A hazard may be cre ated
by damage to critical working parts and safety sys
tems.
Wet Battery Service
If the battery has been shipped wet, but the electro
lyte level is low or the battery needs to be charged
then:
1.
Fill each battery cell with distilled water to the
bottom of the vent wells.
2.
Charge battery. Refer to Battery Charging in
this section.
Battery
Battery Location