5. Operation and Configuration
Predrying temperature Stage 2 (only available if Infrared Technology "OFF")
Predrying for Stage 2 is only available if Stage 1 has also been activated. The parameters are set in the
same way. At this stage, the furnace head is half open.
Value range °C: OFF or 100–700 °C; Value range °F: OFF or 212–1292 °F
Pre-drying holding time Stage 2 (only available if Infrared Technology "OFF")
This parameter defines the duration of the predrying process for Stage 2 once the desired predrying
temperature has been reached.
Value range OFF or 00:00–60:00 (mm:ss)
Thermo Shock Protection (TSP) (only available if Infrared Technology "OFF")
The TSP function protects the dental-lab during the closing process. For this purpose, TSP gauges the tem-
perature of the firing chamber in the furnace head upon the start of the firing program. If required, the
closing path within the set closing time S is adjusted.
Setting options: On/Off
Pre-vacuum
If a firing program is conducted with pre-vacuum, the vacuum pump is switched on at the end of the
closing time (as soon as the furnace head is closed) and run until the pre-vacuum time has elapsed. The
heating phase begins after the pre-vacuum time is over.
The value V1 is ignored upon the start of a program with individually activated pre-vacuum. The vacuum
remains switched on until V2 is reached. V2 must be higher than the stand-by temperature B.
Setting options: OFF or 01:00 – 05:00 (mm:ss)
Hv
Vacuum holding time
With this function, the vacuum share of the holding time can be individually set.
Example: H (Holding time) = 02:00 (mm:ss); if a vacuum share of 50% is desired, the parameter "Vacuum
holding time (Hv)" has to be set to 01:00 (mm:ss).
Setting options: OFF or 00:01 – 60:00 (mm:ss)
Quick opening of the furnace head
If the option "Quick opening of the furnace head" is activated, the furnace head opens at maximum
speed at the end of the holding time.
Setting options: On/Off
Extraction system
If this function is activated, any vapours are extracted during the closing process by means of the vacuum
pump, and fresh air is sucked in for a better firing and drying result.
Setting options: On/Off
Wireless LAN signal strength
If this icon appears in the information bar, the wireless LAN connection is active.
Many thick black lines in the icon indicate a high signal strength.
IoT function
The IoT function can be activated and deactivated here. Moreover, the connectivity status is indicated.
In addition, the time zone can be set in this section
34