Silent Operation; C Heating /Frost Protective Operation - Toshiba RAS-B05E2KVG-E Service Manual

Hide thumbs Also See for RAS-B05E2KVG-E:
Table of Contents

Advertisement

Item
Operation flow and applicable data,etc
17. Silent
Silent
Operation
Silent 1:
Cooling/heating capacity is limited maximum for
70% of rated. Only compressor speed is limited.
Silent 2:
CDU sound level is limited for lowest CDU sound
level. Compressor and CDU fan speed are limited.
Silent Operation description
Model
RAS-B05E2KVG-E
RAS-B07E2KVG-E
RAS-B10E2KVG-E
RAS-B13E2KVG-E
RAS-B16E2KVG-E
RAS-18E2KVG-E
Silent Operation (Outdoor Unit)
18. 8C heating /
8°C
Frost
Set temperature is performed for 5C to 13C
protective
and no cold draft prevention control.
operation
8C heating operation
button on remote controller is pressed.
Cooling
Silent
Compressaor
CDU
Operation
frequncy
Fan speed
(rps)
(rpm)
Silent1
29
normal
Silent2
22
720
Silent1
38
normal
Silent2
29
720
Silent1
41
normal
Silent2
26
720
Silent1
55
normal
Silent2
29
720
Silent1
49
normal
Silent2
28
700
Silent1
58
normal
Silent2
32
700
Press
SILENT#1
Button on remote controller is pressed.
Fireplace#1
Fireplace#2
Normal
operation
This function is used when the user need
to keep silent at outdoor side. It is limit
maximum compressor speed and CDU
fan speed. Sound level can be
implemented by 2 silent level.
Sound level:
Rated level > Silent 1 > Silent 2
Note:
Due to Silent operation reason,
In adequate cooling/heating capacity may
occur.
Heating
Compressaor
CDU
frequncy
Fan speed
(rps)
(rpm)
40
normal
29
720
52
normal
32
720
57
normal
36
720
63
normal
41
720
57
normal
37
700
61
normal
40
700
SILENT#2
None
Intended for cold latitudes and performs
objective heating operation.
8°C
- 53 -
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents