INDOOR UNIT DISPLAY
1 ECO (White)
2 Wi-Fi access (White) w
3 Hi POWER (White)
4 Timer (White)
5 Operation mode (White)
● Display brightness can be adjusted, follow procedure on %.
w Require Wireless LAN connecting adapter which available as accessory.
2
PREPARATION BEFORE USE
Preparing Filters
1. Open the air inlet grille and remove the air fi lters.
2. Attach the fi lters. (see detail in the Installation Manual).
Loading Batteries (when use wireless operation.)
1. Remove the slide cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Clock Setup
1. Push
by tip of the pencil.
If timer indication is fl ashing, go to the next step 2.
2. Press
or
: adjust the time.
3. Press
: Set the time.
Remote Control Reset
Push
by tip of the pencil or
1. Remove the batteries.
2. Press
.
3. Insert the batteries.
3
AIR FLOW DIRECTION
1
Press
: Move the louver in
the desired vertical direction.
Press
: Swing the
2
air automatically and press again to
stop.
For horizontal direction, adjust
3
manually.
Note:
● Do not move the louver manually by others.
● The louver may automation positioning by some operation mode.
4

REMOTE CONTROL

1 Infrared signal emitter
2 Start/Stop button
3 Mode select button (MODE)
4 Temperature button (TEMP)
5 Fan speed button (FAN)
6 Swing louver button (SWING)
7 Set louver button (FIX)
8 8°C Heating Operation (8°C)
9 On timer button (ON)
! Off timer button (OFF)
" Setup button (SET)
# Clear button (CLR)
$ Memory and Preset button (PRESET)
% Silent operation button (SILENT)
& High power button (Hi POWER)
( Eco button (ECO)
) Quiet button (QUIET)
~ Comfort sleep button (COMFORT SLEEP)
+ Filter reset button (FILTER)
, Set clock button (CLOCK)
- Check button (CHECK)
. Reset button (RESET)
Note:
● The provided Remote Controller is a wireless type, which also can be
used as a wire. Please see "How to Connect The Remote Controller
for Wired Operation", located in installation instruction, in case of wired
control is required.
● In wire operation, remote controller will return to initial condition
(PRESET, TIMER and CLOCK will return to initial condition)
when user shutdown power supply of Air conditioner.
1
$
4
2
6
3
5
SWING
FAN
7
)
%
FIX
QUIET
(
&
ECO
Hi POWER
8
#
8°C
9
!
"
~
-
.
,
+
5

SILENT OPERATION

SILENT OPERATION (
)
Keep outdoor unit operating silently to ensure either yourself or neighborhood
will have a tight sleep in nighttime. By this feature, the heating capacity will
be optimized to deliver such silent experience. The silent operation can be
selected from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2
Silent 1:
Though operating silently, the Heating (or Cooling) capacity is still prioritized to
ensure having sufficient comfort inside the room.
This setting is a perfect balance between the Heating (or Cooling) capacity
and the Sound level of outdoor unit.
Silent 2:
Compromising the Heating (or Cooling) capacity to the Sound level in any
circumstance where the outdoor unit's sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor unit
by 4 dB(A).
Note:
● While activating of Silent operation, inadequate heating (or cooling)
capacity may occur.
Silent Operation (Outdoor Unit)
Press
SILENT#1
6

AUTOMATIC OPERATION

To automatically select cooling, heating or fan only operation
1. Press
: Select Auto A.
2. Press
: Set the desired temperature. Min. 17°C, Max. 30°C.
3. Press
: Select AUTO, LOW , LOW+
MED+
or HIGH
7
COOLING / HEATING / FAN ONLY OPERATION
1. Press
: Select Cool
2. Press
: Set the desired temperature.
Min. 17°C, Max. 30°C.
Fan Only: No temperature indication
3. Press
: Select AUTO, LOW , LOW+
MED+
or HIGH
8
DRY OPERATION
For dehumidifi cation, a moderate cooling performance is controlled
automatically.
1. Press
: Select Dry
2. Press
: Set the desired temperature. Min. 17°C, Max. 30°C.
Note: Dry mode fan speed is set to Auto only.
9
Hi POWER OPERATION
To automatically control room temperature and airfl ow for faster cooling or
heating operation (except in DRY and FAN ONLY mode)
Press
: Start and stop the operation.
10
ECO OPERATION
To automatically control room temperature to save energy (except in DRY and
FAN ONLY mode)
ECO
Press
: Start and stop the operation.
Note: Cooling operation; the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase).
For heating operation the set temperature will decrease.
SILENT#2
None
, MED
,
.
, Heat
or Fan only
.
, MED
,
.
.