Input [dBm] – Displays the in-band Downlink/Uplink signal level. The system will display "--.-"when the input
level is < -90 dBm.
·
Gain [dB]
-
User Set: Displays the amount of gain that user set.
-
ALC: Displays the amount of gain that is attenuated by ALC function.
-
ILC: Displays the amount of gain that is attenuated by ILC function.
-
Actual: Displays the actual amount of gain that is currently in use.
·
Output [dB] – Displays the Downlink/Uplink output power levels. The system will display "--.-" when the
output level is < +5 dBm.
·
Isolation [dB] – Displays the measured isolation value. The value inside of the parenthesis is the "actual gain -
measured isolation value". When the "actual gain – measured isolation value" is less than -15dB, then "MAX"
will be displayed.

5.2.3 Alarm

This section displays the alarm status for System alarms, RF Alarms, and Power alarms. If an alarm is present
in the system, then the color of the alarm tab will change according to the type of failure.

5.2.4 Message Board

Displays the 30 most recent events.
Advanced RF Technologies, Inc.
Figure 5-4
Power & Gain Display
Figure 5-5
Alarm Display