Installation; Installing/Replacing The Lamp - Future light EVO-1 User Manual

Lighting effect
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION

Installing/Replacing the lamp

For the installation, you need one EHJ 24 V/250 W G-6,35 lamp.
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Procedure:
Step 1: Unscrew the fixation screws A, B of the lamp system and carefully remove it from the housing.
Step 2: If replacing the lamp, remove the old lamp from the lamp holder.
Step 3: Insert the lamp into the lamp holder.
Step 4: Replace the lamp system in the housing and tighten the fixation screws.
Step 5: Adjust the lamp as described under lamp adjustment.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened cover!
24/63
51837515_V_1_0.DOC

Advertisement

Table of Contents
loading

Table of Contents