10.3.3 Table repeatability and accuracy
Values for sampling rate 15 Hz, extraneous light of max. 40 klx*
Distance
in [mm]
200���1000
1000���2000
2000���4000
4000���6000
6000���10000
Values for sampling rate 15 Hz, extraneous light of 40...100 klx*
Distance
in [mm]
200���2000
2000���4000
4000���6000
6000���10000
*Range referred to black (6 % remission) ≤ 4000 mm.
The values apply at:
• constant ambient conditions (23°C / 960 hPa)
• only after unit powered up for 10 minutes
Repeatability
white
grey
90 % remission
18 % remission
± 4�5 mm
± 5�0 mm
± 16�0 mm
± 24�0 mm
± 50�0 mm
Repeatability
white
grey
90 % remission
18 % remission
± 14�0 mm
± 25�0 mm
± 31�0 mm
± 60�0 mm
white
90 % remission
± 6�0 mm
± 15�0 mm
± 8�0 mm
± 15�0 mm
± 19�0 mm
± 25�0 mm
± 33�0 mm
± 35�0 mm
± 65�0 mm
white
90 % remission
± 14�0 mm
± 24�0 mm
± 30�0 mm
± 35�0 mm
± 45�0 mm
± 41�0 mm
± 70�0 mm
Accuracy
grey
18 % remission
± 16�0 mm
± 18�0 mm
± 30�0 mm
± 45�0 mm
Accuracy
grey
18 % remission
± 24�0 mm
± 40�0 mm
± 55�0 mm