10.3 Teach mode
10.3.1 Setting of the sampling rate
The sampling rate indicates the time after which a new result of
measurement is provided and the outputs are updated�
The switching frequency is typ� approx� 1/3 of the sampling rate�
► Select [TEAC], then press [SET] and keep pressed until [WAIT] is
displayed�
> [rATE] and [rEPr] are displayed alternately�
► When [rATE] is displayed: Press [SET] until the preset measured
sampling rate value flashes�
► Enter a value incrementally by pressing [SET] once�
► Confirm with [MODE/ENTER]�
> [WAIT] is displayed while the repeatability [rEPr] is calculated�
> The sampling rate [rATE] and the repeatability [rEPr] are displayed
alternately�
10.3.2 Setting of the repeatability
► Select [TEAC], then press [SET] and keep pressed until [WAIT] is
displayed�
> [rATE] and [rEPr] are displayed alternately�
► When [rEPr] is displayed: Press [SET] until the preset repeatability
value flashes�
► Enter value incrementally by pressing [SET] once�
► Confirm with [MODE/ENTER]�
> [WAIT] is displayed while the sampling rate [rATE] is calculated�
> The sampling rate [rATE] and the repeatability [rEPr] are displayed
alternately�
10.3.3 Table repeatability and accuracy
Values for sampling rate 5 Hz
Distance
in [mm]
200���1000
1000���2000
2000���3000
3000���3500
22
Repeatability
white
90 % remission
± 6,5 mm
± 8 mm
± 17 mm
± 23 mm
grey
18 % remission
± 7,5 mm
± 9,5 mm
± 19 mm
± 25 mm
Accuracy
white
90 % remission
± 32 mm
± 33 mm
± 42 mm
± 50 mm
grey
18 % remission
± 40 mm
± 40 mm
± 50 mm
± 55 mm