HANDHELD
DIGITAL MULTIMETER
OPERATOR'S
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Mastech CSIMS8264

  • Page 1 HANDHELD DIGITAL MULTIMETER OPERATOR’S INSTRUCTION MANUAL...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents TITLE PAGE TITLE PAGE 3.2.5 Capacitance measurement 1. GENERAL INSTRUCTIONS 3.2.6 Transistor measurement 3.2.7 Frequency measurement 1.1 Precaution safety measures 3.2.8 Temperature measurement 1.1.1 Preliminary 3.2.9 Current measurement 1.1.2 During use 1.1.3 Symbols 4. TECHNICAL SPECIFICATIONS 1.1.4 Instructions 1.2 Protection mechanisms 4.1 General specifications..
  • Page 3: General Instructions

    1. GENERAL INSTRUCTIONS are variable; for that reason, requires that the transient This instrument complies with IEC 1010-1 (61010-1@IEC: withstand capability of the equipment is made known to the 2001), CAT. II 1000V and CAT. III 600V overvoltage user. * When using this Multimeter, the user must observe all standards.
  • Page 4: Symbols

    * To avoid damages to the instrument, do not exceed the * In TV repair work, or when carrying out measurements on maximum limits of the input values shown in the technical power switching circuits, remember that high amplitude specification tables. voltage pulses at the test points can damage the multimeter.
  • Page 5: Instructions

    1.1.4 Instructions 1.2 Protection mechanisms * Fused by the resettable fuse (F200mA/250V) during * Remove test leads from the Meter before opening the capacitance, temperature, mA and hFE measurements. Meter case or battery cover. * A PTC resistor protects against permanent overvoltages of * When servicing the Meter, use only specified replacement up to 380V during resistance, Frequency, continuity and parts.
  • Page 6: Lcd Display

    Table 1. Display Symbols (continued) 2.2 LCD Display The Meter is in the Continuity Check mode. See Table 1 indicated for information about the LCD display. The Meter is in the Data Hold mode ℃: Celsius scale. The unit of temperature. ℃...
  • Page 7: Terminals

    2.4 Terminals See Table 4 indicated for information about the terminals. Table 4. Terminals Terminal Description Return terminal measurements. (Receiving the black test lead or the “com” plug of the special multi-function socket) Input for voltage, resistance, frequency, diode and continuity measurements. (Receiving the VΩHz red test lead) Input for capacitance, Temperature, hFE and...
  • Page 8: Function Description

    1. Set rotary switch to the proper range. 3. FUNCTION DESCRIPTION 2. Connect the black and red test leads to the COM and 3.1 General Functions V terminals respectively. 3. Connect the test leads to the circuit being measured 3.1.1 DATA HOLD mode 4.
  • Page 9: Diode Test

    ¥ The measured value of a resistor in a circuit is often 1. Set the rotary switch to range. different from the resistor's rated value. This is because 2. Connect the black and red test leads to the COM and the Meter's test current flows through all possible paths terminals respectively.
  • Page 10: Capacitance Measurement

    Note: To avoid electrical shock and/or damage to the ¥ Continuity test is available to check open/short of the instrument, do not apply more than 250Vdc or circuit. 250Vac rms between the hFE terminal and the COM terminal. 3.2.5 Capacitance measurement To avoid electrical shock and/or damage to the 1.
  • Page 11: Current Measurement

    and 10.00A;AC current ranges are 2.000mA, 200.0mA To avoid electrical shock and/or damage to the and 10.00A. instrument, do not apply more than 250Vdc or To measure current: ℃ 250Vac rms between the terminal and the 1. Turn off the power of the measured circuit. Discharge all COM terminal.
  • Page 12: General Specifications

    4.1 GENERAL SPECIFICATIONS Accuracy is specified for one year after calibration, at ¥ Environment conditions: operating temperatures of 18 ℃ to 28 ℃ , with relative 1000V CAT. II and 600V CAT. III humidity at 0% to 75%. Pollution degree: 2 Accuracy specifications take the form of: ±(% of Reading + Altitude <...
  • Page 13: Transistor

    Range Resolution Accuracy * Temperature specifications do not include thermocouple ±(0.8% of rdg+3 digits) errors. 200Ω 0.1Ω 2kΩ 1Ω 4.2.9 Capacitance 20kΩ 10Ω ±(0.8% of rdg+1 digit) Range Resolution Accuracy 200kΩ 100Ω 2MΩ 1kΩ 20nF 10pF ±(1.0% of rdg+2 digits) 20MΩ...
  • Page 14: General Maintenance

    ¥ Do not attempt to repair or service your Meter unless you are Use a screwdriver to unscrew the two screws secured on qualified to do so and have the relevant calibration, the battery cover. ¥ Take out the battery cover from the meter. performance test, and service information.