Function
Name
code
Carrier frequency
b083
setting
Brake control enable
b120
Digital current monitor
C030
reference value
Low-current indication
C039
signal detection level
Overload level setting
C041
Over-torque
(forward-driving) level
C055
setting
Over-torque (reverse
regenerating) level
C056
setting
Over-torque (reverse
C057
driving) level setting
Over-torque (forward
regenerating) level
C058
setting
Overload setting (2)
C111
Note: < > indicate the setting range of 75 to 150kW
Heavy load (CT)
Range
0.5 to 15.0(kHz)
<0.5 to 10.0(kHz)>
00 (disabling), 01 (enabling)
0.20 x Rated current to 1.50 x
Rated current (A)
(Current with digital current
monitor output at 1,440 Hz)
0.00 to 2.00 x rated current(A)
<0.00 to 1.80 x Rated current(A)>
0.00 to 2.00 x rated current (A)
<0.00 to 1.80 x Rated current(A)>
0. to 200.(%)
<0. to 180.(%)>
0.00 to 2.00 x rated current
<0.00 to 1.80 x Rated current(A)>
3-24
Normal load (VT)
default
Range
5.0(kHz)
0.5 to 12.0(kHz)
<3.0(kHz)>
<0.5 to 8.0(kHz)>
00
00 (disabling)
(disabling)
Rated
0.00 to 1.50 x Rated current
current (A)
(A)
Rated
0.00 to 1.50 x Rated current
current (A)
(A)
Rated
0.00 to 1.50 x Rated current
current (A)
(A)
100(%)
0. to 150.(%)
Rated
0.00 to 1.50 x Rated current
current (A)
(A)
Operation
default
3.0(kHz)
00
(disabling)
Rated
current (A)
Rated
current (A)
Rated
current (A)
100(%)
Rated
current (A)