5) Unplug the icemaker or disconnect the power source when the water pan has fully
opened.
6) Remove all ice from the storage bin, and clean the bin.
7) Replace the front panel in its correct position.
8) Replace the inlet hose in its correct position.

[b] IM-100, 130, 240

1) Close the water supply tap, and remove the
inlet hose.
2) Remove the front panel.
3) Remove the screw located on the front of the
water tank.
4) Move the tank drain pipe to the drain position.
See Fig. 2.
5) Push the reset switch. The water pan will start
to open.
6) Blow out the water supply line immediately after
the water pan has opened.
Note: This procedure is necessary to protect the
icemaker from freezing up at subfreezing
temperature.
7) Unplug the icemaker or disconnect the power
source when the water pan has fully opened.
8) Move the tank drain pipe to the normal position, and secure it with the screw.
9) Remove all ice from the storage bin, and clean the bin.
10) Replace the front panel in its correct position.
11) Replace the inlet hose in its correct position.
34
[Normal Position]
Tank Drain
Pipe
[Drain Position]
Fig. 2
Screw