10 | Smart Thermostat Product Manual
Connect the Thermostat to the System
1. Put the thermostat in OFF mode
(No mode icons are lit).
2. Put the Z-Wave controller into inclusion mode.
Refer to the controller documentation for
more information.
3. Press and hold the DOWN
button on the
thermostat to begin inclusion mode. Release the
button when the RADIO
icon lights up.
4. When the RADIO
icon becomes solid, the
thermostat has been included.
5. Login to your online account (www.alarm.
com/login) to sync the thermostat with the
Alarm.com system, or contact an Alarm.com
professional for installation setup.
Write your login information below once you
have chosen a personal password.
User ID:
Password:
CONFIGURE THE SYSTEM
The thermostat configuration will be done on
your online account. Here you can configure the
parameters of the system, such as: Heat Pump or
Normal, number of heat and cool stages, heating
fuel, calibration temperature, and configurable
terminal (Z). In your online account, you will have
to enter the thermostat configuration. Refer to
page 7 for the appropriate diagrams when you
set up the thermostat.
While the default settings will be sufficient in
most cases, you also have the option to change
advanced configuration settings, such as: Swing,
Differential, Recovery Settings, Fan Circulation
Period and Duty Cycle, Maximum Set Points,
Minimum Set Points and Thermostat Lock.
The thermostat can be configured locally for the
most common configurations. Please see Page 12
for instructions.
WARNING: Use caution when changing
advanced configuration settings.
These configuration settings should only be
changed by those familiar with heating and
cooling systems' parameters. Contact a
local HVAC professional for help.
Smart Thermostat Product Manual | 11
CHECK THE SYSTEM
WARNING: Do not test the AC during cold
weather or heat during hot weather.
Wait for mild weather to fully test the system.
To Check Heating
1. Press the MODE
button to select
HEAT
mode.
2. Press the UP
button to raise the set point
above room temperature.
3. Wait 5 minutes for the system to turn on.
4. After verifying the heating system is working,
return the set point to the desired temperature.
To Check Cooling
1. Press the MODE button
to select
COOL
mode.
2. Press the DOWN
button to lower the set
point below room temperature.
3. Wait 5 minutes for the system to turn on.
4. After verifying the cooling system is working,
return the set point to the desired temperature.
Need help?
Do you have a question about the ADC-T2000-RC and is the answer not in the manual?