Power Source Selection Menu - Miller S-74DX Owner's Manual

Table of Contents

Advertisement

5-6. Power Source Selection Menu

* * Power Source
Deltaweld 452
Deltaweld 302
Deltaweld 652
Dimension 302
Dimension NT 450
Dimension 452
Dimension 652
Dimension 1000
XMT 304
XMT 350
XMT 456
Invision 350 MPa
Invision 354MP
Invision 456MP
Invision 456P
PHOENIX 456
SUMMIT ARC 1000
** For any power sources not listed, pick a matching voltage range, or see Sec 5-10 to
set Vmin and Vmax.
OM-1500-9 Page 18
1
Upper Display
Lower Display
dELT
452
dELT
302
dELT
652
dIM
302
dIM
450
dIM
452
dIM
652
dIM
1000
XMT
304
XMT
350
XMT
456
I350
MPa
I354
MP
I456
MP
I456
P
PHX
456
SUM
1000
2
Voltage Range
Vmin =10
Vmax =38
Vmin =10
Vmax =32
Vmin =10
Vmax =44
Vmin =10
Vmax =32
Vmin =10
Vmax =38
Vmin =10
Vmax =38
Vmin =10
Vmax =65
Vmin =10
Vmax =60
Vmin =10
Vmax =35
Vmin =10
Vmax =38
Vmin =10
Vmax =38
Vmin =10
Vmax =38
Vmin =10
Vmax =35
Vmin =10
Vmax =38
Vmin =10
Vmax =38
Vmin =10
Vmax =38
Vmin =25
Vmax =44
1
Upper Display
2
Lower Display
.
When the feeder is turned on,
the Power Source Selection
Menu allows the operator to se-
lect a default power source.
Selecting a default power
source, automatically sets the
correct Vmin and Vmax set-
tings for adjusting the output
voltage of the power source.
First Time Feeder Is Turned On
The feeder automatically goes into
the Power Source Selection Menu.
The feeder displays "dELT" on the
Upper Display and "452" on the
Lower Display, meaning that a Del-
taweld 452 is the default power
source, and has a voltage range of
10V as Vmin and 38V as Vmax.
At power up, the operator has three
seconds to select a default power
source from the list shown on the
display.
Operator
may
scroll
through the list of power sources by
using the Adjust control. After se-
lecting a power source the operator
has three seconds to change to a
different power source or begin
welding. After making a power
source selection, the operator may
press the Program Button to avoid
having to wait the three seconds.
When turning off the feeder, the de-
fault power source will be retained.
If voltage settings have already
been set with the Vmin and Vmax in
the Auxiliary Menu, selecting a de-
fault power source with the Power
Source Selection Menu overrides
the Vmin and Vmax voltage set-
tings.
Next Time Feeder Is Turned On
The feeder will display the last se-
lected default power source. The
operator has three seconds to se-
lect another power source, or press
the Program Button to exit the Pow-
er Source Selection Menu.
Disabling The Power Source
Selection Menu
Once the default power source has
been selected the Power Source
Selection Menu may be disabled
using the Auxiliary Menus. See
Section 6-10.

Advertisement

Table of Contents
loading

This manual is also suitable for:

300618300618001300618002300618003300618006

Table of Contents