QC Industries AUTOMATION AS40-CD Installation & Maintenance Instructions Manual page 12

Table of Contents

Advertisement

Belt Change
u Removal of Existing Belt
Full width idlers must be removed before changing belt.
>
1
Simultaneously push in
both buttons on tension
release tail to disengage locking
mechanism. (Frame end could have
sharp edges)
2
x
5
Loosen screws on stand. (Do
not remove)
9
Remove guard.
12
AS40-CD Conveyors | Installation & Maintenance Instructions
2
Rotate tension release tail
assembly up and towards the
drive end.
6
Slide stand bracket down for
clearance.
10
Loosen both adjustment
screws on drive pulley
side to allow clearance for idler
pulley removal.
2
x
3
Loosen screws on mounts/
brackets on opposite side
of drive.
4
x
7
Remove four screws holding
guard from frame on drive
pulley side.
11
Slide idler pulley out of
slot and set aside.
2
x
4
Remove screws from stand
brackets or mounts. (If stand
brackets are not used, proceed to
step 7)
2
x
8
Remove two screws holding
guard on opposite side above
motor.
12
Loosen both adjustment
screws on motor side
to allow clearance for idler pulley
removal.

Advertisement