12.10 Quiet Operation
(For Cooling Operation or cooling region of Soft Dry Operation)
•
To provide quiet cooling operation condition.
•
Once the Quiet Operation is set at the remote control, the Quiet LED illuminated. The sound level will reduce
around 2dB(A) for Lo fan speed or 3dB(A) for Hi/Me fan speed against the present operation sound level.
•
Dew formation become severe at Quite Lo Cool, therefore Quiet Lo cool operated only for 2 hours (1 hour QLo,
1 hour QLo + 80rpm) (for A9KKD-2 and A12KKD-2) or only 1 hour 30 minutes (1 hour QLo, 30 minutes QLo + 50
rpm) (for A18KKD-2 and A24KKD-2) or only 1 hour 30 minutes (1 hour QLo, 30 minutes QLo + 100 rpm) (for
A28KKD-2).
•
Manual Airflow Direction:
RPM control during Lo cool
o
(For A9KKD-2 and A12KKD-2)
(For A18KKD-2 and A24KKD-2)
(For A28KKD-2)
RPM control during Hi & Me cool
o
67