Operation mode will be determine again for judgement after 1 hour of operation, if the room temperature reaches
to set temperature and compressor off time is over 7 minutes 30 seconds continuously.
* The present operation mode will be continued, if the room temperature does not reach to set temperature
(Compressor keeps running) eventhough after 1 hour from automatic operation mode started.
Standard for Determining Operation Mode
2nd Judgement onwards
Present Mode
Cooling
Soft Dry
Heating
Automatic Set Temperature
For each operation, set temperature will automatically set as shown below.
The setting temperature for all the operations can be changed one level up or one level down from the standard
temperature as shown in below table by pressing on the temperature up or temperature down button at remote
control.
The operation mode judging temperature and standard setting temperature can be increased by 2°C
permanently, by open the circuit of JX03 at indoor unit's printed circuit board.
Judgement
Cooling
23°C
Heating
Soft Dry
20°C
Heating
Cooling
25°C
Heating
Operation
Cooling
Soft Dry
Heating
Cooling
O
(Judgement:
23°C & Above)
Not Applicable
O
(Judgement:
25°C & Above)
Hi
(Standard)
(+2°C)
(±0°C)
27°C
25°C
24°C
22°C
23°C
21°C
56
Next Mode
Soft Dry
Not Applicable
O
(Judgement:
20°C & Above)
Not Applicable
Lo
(-2°C)
23°C
20°C
19°C
Heating
O
(Judgement:
Below 23°C)
O
(Judgement:
Below 20°C)
O
(Judgement:
Below 25°C)