Cs-A12Kkd-2 Cu-A12Kkd-2 - Panasonic CS-A9KKD-2 Service Manual

Table of Contents

Advertisement

8.2

CS-A12KKD-2 CU-A12KKD-2

Resistance of Indoor Fan Motor Windings
MODEL
CONNECTION
BLUE-YELLOW
YELLOW-RED
Note: Resistance at 20°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
MODEL
CONNECTION
BLUE-YELLOW
YELLOW-RED
Note: Resistance at 25°C of ambient temperature.
CS-A12KKD-2
CWA921415
196Ÿ
303Ÿ
CU-A12KKD-2
CWA951121J
200.4Ÿ
252.5Ÿ
Resistance of Compressor Windings
MODEL
CONNECTION
C-R
C-S
Note: Resistance at 20°C of ambient temperature.
28
CU-A12KKD-2
2PS206D2BA02
3.207Ÿ
3.256Ÿ