Using The Features - Greenlee DML-430 Instruction Manual

Greenlee dml-430 digital meters: user guide
Table of Contents

Advertisement

Available languages

Available languages

Using the Features

Automatic Power Off To extend battery life, the meter will shut itself off after approximately
START ||
SELECT
RANGE
Hz
Hold
8
17 minutes of inactivity. To restore power, press SELECT. To disable this
feature, press RANGE while turning the meter on.
Used for storing, reviewing and retrieving data. See the explanation
under Data Storage Function.
The Automatic Power Off feature is disabled when using this function.
Press and hold to illuminate the LCD. The lamp turns off after 30
seconds to extend battery life.
Press momentarily to toggle between functions, or to toggle between AC
and DC when measuring current and millivolts.
Press once to enter the manual ranging mode. The
disappear from the display. Press repeatedly to step through the ranges.
Press and hold to return to the automatic ranging mode.
Note: When using MAX/MIN, Hold, or
cause the meter to exit that mode.
Press to measure frequency.
Note: The sensitivity of the frequency measurement function varies
with the measurement range. To automatically select a sensitivity
level, measure the voltage level first, then press Hz. If the
reading becomes unstable, or if the display is blank, manually
change the sensitivity by momentarily pressing RANGE.
Press momentarily to hold the present value on the display. Press again
to exit this mode.
icon will
mode, pressing RANGE will

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dml-54

Table of Contents