Greenlee DML-430 Instruction Manual page 20

Greenlee dml-430 digital meters: user guide
Table of Contents

Advertisement

Available languages

Available languages

Accuracy (cont'd)
Capacitance
Range
49.99 nF
(0.8% + 0.03 nF)
499.9 nF
4.999 F
(1.0% + 0.003 F)
49.99 F
(2.0% + 0.03 F)
499.9 F
9999 F
Notes: Accuracies are for film capacitors (capacitors with negligible dielectric absorption).
Measurements of larger capacitors can take up to 30 seconds.
Temperature
Range
-50 C to 1000 C
Note: The accuracy information is for the meter only; see the information sheet provided with
your temperature probe (purchased separately) for its accuracy.
Diode Test
Measuring Range: 2.000 V
Test Current (Typical): 0.8 mA
Open Circuit Voltage: Less than 3.5 VDC
Continuity
Threshold: Tone indicates continuity. The threshold is between 20 and 200
Response Time: Less than 100 s
20
Accuracy
(0.8% + 0.3 nF)
(3.5% + 0.5 F)
(5.0% + 5 F)
Accuracy
(0.3% + 3 C)

Hide quick links: