Installation Site And Position - ABB PVS-175-TL-SX2 Product Manual

175 kw
Table of Contents

Advertisement

I
nstallation site and position
Please refer to the warranty terms and conditions to evaluate any possible warranty exclu-
sions due to improper installation.
General recommendation on installation position
• Consult the technical data to check the required environmental condi-
tions (protection rating, temperature, humidity, altitude, etc.).
• Installation of the unit in a location exposed to direct sunlight NOT accepta-
ble. (Add awning in case of direct sunlight installation).
• Final installation of the device must not compromise access to any dis-
connection devices that may be located externally.
• Do not install in small closed rooms where air cannot circulate freely.
• Always ensure that the flow of air around the inverter is not blocked so
as to prevent overheating.
• Do not install near flammable substances (minimum distance 3 m).
• Do not install on wood walls or other flammable supports.
• Install on a wall or strong structure suitable to bear the weight.
• Do not install in rooms where people live or where the prolonged pre-
sence of people or animals is expected, because of the high noise that
the inverter produces during operation. The level of the sound emission
is heavily influenced by where the appliance is installed (for example:
the type of surface around the inverter, the general properties of the
room, etc.) and the quality of the electricity supply.
Tilting admittance
• The installation can be carried out with a maximum inclination as indi-
cated in the figures below.
NO
OK
Vertical tilting
- 51 -
5 - Installation
±1° max
PVS-175
Side tilting