Mutual Connection Of Multiple Inverters; Notes On The System Sizing - ABB PVS-175-TL-SX2 Product Manual

175 kw
Table of Contents

Advertisement

M
utual connection of multiple inverters
If the photovoltaic system exceeds the capacity of a single inverter, it is
possible to connect multiple inverters to the system, each of them in turn
connected on the DC side to a separate section of the photovoltaic gen-
erator, and on the AC side to the distribution grid.
Each string inverter will work independently of the others and its own
photovoltaic module will supply the maximum power available to the grid.
N
otes on the system sizing
Decisions on how to structure a photovoltaic system depend on a series of factors and con-
siderations, such as the type of panels, the space availability, the future location of the sys-
tem, energy production goals over the long term, etc.
A configuration program that can help to correctly size the photovoltaic
system is available on the ABB website (http://stringsizer.abb.com).
When configuring DC input and during the installation it's needed to follow one basic rule to
avoid possible output power derating: All MPPTs shall be populated connecting at least one
string. Considering to connect 20 strings, proceed connecting one string per MPPT and then
connect the remaining strings in the selected MPPTs where you want to use 2 strings.
- 34 -
3 - Characteristics

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pvs-175-tl

Table of Contents