Technical Specifications; Switched Metered By Outlet/Switched - CyberPower PDU83101 User Manual

3-phase power distribution unit
Table of Contents

Advertisement

Product Features:

Switched Metered by Outlet/Switched

(16/20A Models)
A. AC Inlet/ AC Power Cord - Used to connect PDU to utility
power or UPS.
B. Outlet Indicator (Switched Series only) - Indicates if the
outlet is providing power to connected equipment.
C. AC Output Receptacles - Provides power for connected
equipment.
D. Status Indicator - Indicates the condition of the PDU (eg.
load or environment status)
E. Multifunction LCD Readout - Displays various PDU
information such as power and load condition.
F. Ethernet Port – Used to connect PDU to the network.
G. ENVIROSENSOR/ Daisy Chain (In) Port (RJ45 modular port)
– Used for ENVIROSENSOR or chaining to previous PDU.
H. USB Port - Used to upgrade the firmware via a flash drive.
I. Serial Port (RJ45 modular port) - Used to connect to a PC
and control the PDU locally via SSH/Telnet.
J. Daisy Chain (Out) Port – Used for chaining to next PDU..
K. Select Button - Used to control the LCD screen and toggle
through the available information options
L. Enter Button - Used to choose selected items, enter to next
level menu or return to previous menu.
M. Bracket Screw Hole - Used to secure the Mounting Pegs (pre-
installed) or Mounting Brackets.

Technical Specifications

Model Name
Input
Nominal Voltage
Frequency
Maximum Input Current
Plug Type
Power Cord Type
Power Cord Length
Output
Nominal Voltage
Maximum Output Current
Outlet Type
Outlet Number
Management and Communications
Multifunction LCD Readout Voltage, Frequency, Load, Current, HW/FW Version, Network Information
Software
Networking
Serial Port
Sensor Capable
Physical
Dimensions (H x W x D)
Environmental
Humidity
Altitude
Temperature
Safety Approvals
Certifications
* All specifications are subject to change without notice
PDU83101
PDU83102
PDU43101
PDU43102
208V
16A UL (Derated)
NEMA L21-20P
120V
16A UL (Derated)
(30) NEMA
5-20R
PowerPanel® Business Edition
70.5" x 2.2" x 2.2" / 1790mm x 56mm x 55mm
o
o
23
F to 140
F / -5
UL60950-1, UL62368-1. FCC Class A
5
PDU83103
PDU43103
200-240V
50/60Hz
NEMA
L15-20P
SR (12 AWG)
10 ft / 3.05 m
200-240V
(24) IEC 320 C13 (6) IEC 320 C19
30
Yes
RJ45
Optional
0 to 95% Non-condensing
11480ft / 3500m
o
o
C to 60
C
PDU83111
PDU83401
PDU43111
PDU43401
346-415V
16A CE
IEC 309
IEC 309
20A Red
16A Red
(3P+N+E)
(3P+N+E)
16A CE
o
o
23
F to 131
F /
o
o
-5
C to 55
C
CB, CE
.
EN55032/24
Class A

Advertisement

Table of Contents
loading

Table of Contents