Emax HULK POWER HP01P005SS Operating Instructions Manual

Emax HULK POWER HP01P005SS Operating Instructions Manual

Portable air compressor
Hide thumbs Also See for HULK POWER HP01P005SS:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Operating Instructions
EMAX designs and manufactures products for safe
operation. However, operators and maintenance per-
sons are responsible for maintaining safety. All safety
precautions are included to provide a guideline for
minimizing the possibility of accidents and property
damage while equipment is in operation.
Keep these instructions for reference.
Portable Air Compressor
HP01P005SS
Model # :
815002013961
UPC:
EMAX Compressor
1000 Cass Dr., Clayton, OH 45315 USA
866.294.4153
info@emaxcompressor.com
Fax: (937) 540-1157
HP01P005SS man v.171212

Advertisement

Table of Contents
loading

Summary of Contents for Emax HULK POWER HP01P005SS

  • Page 1 Operating Instructions EMAX designs and manufactures products for safe operation. However, operators and maintenance per- sons are responsible for maintaining safety. All safety precautions are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in operation.
  • Page 2: Table Of Contents

    HULK Power Contents Model Specifications ………………………… 2 Installing the air filter …………………………8 Description ……………………………………… 3 Operation ………………………………………… 8 Get to know your compressor …………………3 Before operating your air compressor: …8 Safety Information …………………………… 4 General Overview ……………………………… 8 Basic Guidelines ……………………………… 4 Installation and Location ………………………8 Breathable Air ………………………………………4 Connecting to Power Source …………………8...
  • Page 3: Description

    Air Compressor Description fig 1 Get to know your compressor Please refer to fi g 1. valve end to check that it is working properly. 1. TANK DRAIN VALVE 5. RESERVOIR AIR PRESSURE GAUGE - (located on bottom of tank) - The tank drain Indicates pressure of compressed air built up in valve can be opened to allow moisture and the tank.
  • Page 4: Safety Information

    HULK Power Basic Guidelines Always make sure that the NO T I CE compressor power switch is in the OFF position before performing any maintenance 1. Allow only trained, authorized persons who or plugging the compressor into a power supply. have read and understood these operating 7.
  • Page 5: Personal Protective Equipment

    Air Compressor 5. If the air tank develops a leak, replace it Mount unit leaving a minimum of 15 inches (38 immediately. Never repair, weld or make cm) of clearance. modifications to the air tank or its attachments. 3. Use shims to level compressor if installation 6.
  • Page 6: Operation

    HULK Power 10. Avoid body contact with grounded surfaces substances are spilled, clean up immediately. such as pipes, radiators, ranges, and 8. When checking or when refilling air line anti- refrigerators. There is an increased risk of icer systems with antifreeze compound, shut electric shock if your body is grounded.
  • Page 7: Air Tool Cautions

    Air Compressor as serious damage to equipment or personal untrained persons. injury could result from excessive air pressure. Tools may be dangerous in the hands of untrained users. 20. Compressed air from the unit may contain carbon monoxide. Air produced is not suitable 7.
  • Page 8: Connect To Power Source

    HULK Power used (C, fig 5) it must be attached to the metal screw check that all pipes and hoses are firmly of the receptacle. connected. ● Do not use the air compressor if any damage is The use of an adaptor plug is illegal NO T I CE found.
  • Page 9: Attaching An Air Hose

    Air Compressor cord is properly wired and in good electrical Pressure Switch condition. 2. Check that the pressure switch is pointed up, ● Maximum length of extension cord should be in the OFF position (fi g 9.0). 50 feet (15 meters). Minimum wire size of extension cord should be 12 gauge.
  • Page 10: Shutting Off Your Compressor

    HULK Power Shutting off your compressor 1. Move the pressure switch clockwise to the OFF Maintenance position (fig 9.0). 2. Unplug the compressor from the electical power. Daily 3. If not draining the tank, reduce tank pressure ● Before each use, through the air hose.
  • Page 11: Troubleshooting

    Air Compressor Troubleshooting Always inspect the compressor before use, and make sure it is in good working condition. Make sure all air vents are clear. Check the power cable to make sure it is intact and free from cracks, bare wires etc. Avoid using solvents when cleaning plastic parts, most plastics are susceptible to damage from the various types of commercial solvents.
  • Page 12: Parts List

    HULK Power Parts List Description Qty. Description Qty. Outside spring Filter cover Capacitor Filter element Bolt Filter base Capacitor cover Bolt Bolt Washer Spring washer O-ring Gasket Connecting pipe Power cord Shroud Bolt Pipe Cylinder head Safety valve Rubber mat Pressure gauge Bolt Manifold...
  • Page 13: Schematic Drawing

    Air Compressor Schematic Drawing HP01P005SS man v.171212...
  • Page 14: Warranty Statement

    HULK Power Warranty Statement HULK makes every effort to ensure that this product meets high quality and durability standards. HULK warrants to the original retail consumer a 2-year limited warranty as of the date the product was purchased at retail and that each product is free from defects in materials. Warranty does not apply to defects due directly or indirectly to misuse, abuse, negligence or accidents, repairs or alterations and lack of maintenance.
  • Page 15 Air Compressor HP01P005SS man v.171212...
  • Page 16 HULK Power...
  • Page 17 Mode d'emploi EMAX conçoit et fabrique des produits pour un fonctionnement sécuritaire. Cependant, les opérateurs et les personnes chargées de l'entretien sont responsables du maintien de la sécurité. Toutes les précautions de sécurité sont incluses pour fournir une ligne directrice pour minimiser la possibilité...
  • Page 18 Compresseur à air HULK Power Table des matières Spécifications du modèle …………………… 16 Avant d'utiliser votre nouveau compresseur d'air: ……………………………………………………23 Description ……………………………………… 17 Présentation générale ……………………… 23 Apprenez à connaître votre compresseur 17 Installation et localisation ……………………23 Informations de sécurité …………………… 18 Raccordement à...
  • Page 19: Description

    Série Silent Air ™ Description fig 1 Apprenez à connaître votre compresseur 4. SOUPAPE DE SÉCURITÉ - La soupape de Veuillez vous reporter à la fi gure 1. sécurité dégage 1. SOUPAPE DE DRAINAGE automatiquement la (située au bas du réservoir) - La soupape de pression du vidange du réservoir peut être ouverte pour réservoir d'air en cas...
  • Page 20: Informations De Sécurité

    Compresseur à air HULK Power 6. INTERRUPTEUR DE PRESSION - compresseur. Ceci est prévu pour la SÉCURITÉ et pour ÉVITER LES PROBLÈMES D'ÉQUIPEMENT. Contrôlé par Pour aider à comprendre cette information, le levier de l'interrupteur conservez ce qui suit: d'alimentation Danger indique une situation D A N G ER à...
  • Page 21: Air Respirable

    Série Silent Air ™ blessure. Évitez les infections en prenant soin ses commandes sont conformes à toutes les de petites coupures et de brûlures rapidement. réglementations, codes et normes OSHA, fédéraux, provinciaux et locaux applicables aux équipements Air respirable de protection individuelle. Cela comprend un équipement de protection respiratoire, une protection 1.
  • Page 22: Sécurité Électrique

    Compresseur à air HULK Power NE PAS installer de compresseur 8. L'appareil doit être correctement mis à la terre. DA N G ER dans la salle de chaudière, la NE PAS connecter le fil de terre à l'air ou aux lignes de refroidissement.
  • Page 23: Précautions Sur L'outil Pneumatique

    Série Silent Air ™ 13. Vérifiez l'état des tuyaux avant chaque extincteurs appropriés et à pleine charge à utilisation. N'utilisez pas de tuyau proximité lors de l'entretien et de l'utilisation du endommagé. Si le tuyau est endommagé, compresseur. remplacez-le immédiatement. 2.
  • Page 24: Alimentation De La Source

    Compresseur à air HULK Power 4. Gardez la zone de travail propre et bien du disjoncteur nuisible lors de l'utilisation de votre éclairée. Les zones de travail encombrées ou outil. Des performances incorrectes et/ou des obscures invitent des accidents. dommages à l'outil se produiront si une puissance insuffisante ou excessive est exploitée.
  • Page 25: Assemblage

    Série Silent Air ™ Présentation générale vous aurez besoin. Articles inclus dans la boîte: ● Compresseur d'air Installation et localisation ● Filtre à air ● Mode d'emploi Placez le compresseur dans un endroit propre, sec et bien ventilé. Le compresseur doit être placé à 12 Gardez l'emballage au cas où...
  • Page 26: Soupape De Vidange

    Compresseur à air HULK Power Utiliser uniquement des tuyaux d'air Interrupteur de pression AV I S évalués pour une utilisation avec une pression d'air de 125 psi ou plus haute. 2. Vérifi ez que le pressostat est orienté vers le Pour installer un tuyau d'air équipé...
  • Page 27: Arrêt De Votre Compresseur

    Série Silent Air ™ • Pour augmenter la pression d'air, tourner le dans une prise électrique de 120 volts. N'utilisez bouton du régulateur d'air (fig. 7.10) dans le pas une rallonge lorsque vous démarrez votre sens des aiguilles d'une montre. compresseur par temps froid.
  • Page 28 Compresseur à air HULK Power Problème Cause possible Action corrective La pression dans le réservoir Fuites d'air aux joints 1. Permettre au compresseur de bâtir tombe la pression dans le réservoir, à la pression maximale si possible. Pul- vériser de l'eau savonneuse sur toutes les connexions d'air et chercher des bulles.
  • Page 29: Déclaration De Garantie

    Série Silent Air ™ Déclaration de garantie HULK met tout en œuvre pour s'assurer que ce produit répond à des normes de qualité et de durabilité élevées. HULK garantit au consommateur une garantie limitée de 2 ans à compter de la date à laquelle le produit a été...
  • Page 30: Liste De Pièces

    Compresseur à air HULK Power Liste de Pièces Description Qté. Description Qté. Ressort extérieur Couvercle-filtre Condensateur Élément filtrant Boulon Boîtier du filtre Couvercle du condensateur Boulon Boulon Rondelle Rondelle de resort Joint torique Joint d’étanchéité Raccordement bionique Cordon d’alimentation Enveloppe Écrou Boulon Tuyau...
  • Page 31: Dessin Schématique

    Dessin schématique Série Silent Air ™ HP01P005SS man v.171212...
  • Page 32 Compresseur à air HULK Power...

This manual is also suitable for:

815002013961

Table of Contents