Checking The Hydraulic Fluid Level - Toro TRX-19 Operator's Manual

Trencher
Hide thumbs Also See for TRX-19:
Table of Contents

Advertisement

Figure 16
1. Oil filler hole
2. Oil dipstick
4. Remove the dipstick and wipe the end clean
(Figure 16).
5. Slide the dipstick fully into the dipstick tube without
threading it into the filler neck (Figure 16).
6. Pull the dipstick out and look at the end. The
oil should be between the Add and Full marks
(Figure 16).
7. If the oil is below the Add mark, add 10w30 engine
oil to the filler hole, checking the level frequently
with the dipstick, until the oil level reaches the Full
mark.
8. Replace the dipstick.
Checking the Hydraulic Fluid
Level
Service Interval: Every 25 hours
Hydraulic Tank Capacity: 6 US gallons (23 l)
Use 10W-30 or 15W-40 detergent, diesel engine oil (API
service CH-4 or higher).
1. Park the machine on a level surface and lower the
boom.
2. Stop the engine, remove the key, and allow the
engine to cool.
3. Look into the glass bubble on the right side of the
machine. If you cannot see hydraulic fluid in the
bubble, continue this procedure to add fluid.
3. Full mark
4. Add mark
1. Hydraulic fluid check bubble
4. Remove the cover plate; refer to Removing the
Cover Plate.
5. Clean the area around the filler neck of the hydraulic
tank and remove the cap and filter from the filler
neck using a socket (Figure 18).
1. Filler neck cap
6. If the level is low, add fluid until it is visible in the
glass bubble.
7. Install the cap and filter on the filler neck and torque
bolt on top to 110 to 140 inch-lb (13 to 15.5 N-m).
18