Technical data

Dimensions (W x L x H)
Mains/line voltage
Power input
Air volume
Temperature range
Accuracy
Vacuum
Compressed air connection
Main fusing
Protection class

2. Placing in operation

Place the hand-piece with the hot air nozzle installed in the safety stand AKT 30. (Without the safety
stand or optional WBH 30000S Circuit Board Holder the unit cannot be placed in operation.)
For operation of the WHA 3000V, clean, dry compressed air or, alternatively, nitrogen N
The compressed air connections (18, 19) are on the rear side of the unit. For connection of the
compressed air supply, a compressed air hose with an outside diameter of 6 mm, which is suitable
for operating pressure, is required.
The nitrogen connection (19) serves to generate hot air.
The compressed air connection (18) serves to generate vacuum by means of a compressed air
converter.
If a separate nitrogen supply is not used, the compressed air connections (18) and (19) can be
linked to the Y-connector and supplied with normal compressed air.
Plug cable from safety stand or optional WBH 3000S Circuit Board Holder (proximity switch), into
socket (20). Check whether the mains voltage matches the information on the rating plate. If the
mains voltage is correct, connect the controller to the mains. When the device is switched on, the
device name "WHA 3000" and the software "Version" are displayed briefly. The electronics then
switch automatically to the default setting (Manual operating mode).

2.1 Manual operating mode

Information on
the display(1)
In the Manual operating mode, the parameters for nozzle temperature, air flow rate and Switching
on or off the pre- heating can be set.
Find Quality Products Online at:
: 240 (9.44) X 270 (10.63) X 101 (3,97) mm (inches)
: 230 V (120 V) AC
: 475 W
: 5 – 50 l/min.
: 50°C – 550°C
: + - 30°C (+ - 54°F)
: 0.6 bar
: 400 - 600 kPa
: 230 V / T3,15 A (120 V / T6,3 A)
: 1 (control unit and handpiece hard grounded)
TEMP
350 °C
Nozzle
Air
Temp.
Flow Rate
in °C
in l/min
GlobalTestSupply
www.
AIR
PREHEAT
25 l
OFF
Factory setting
Nozzle
Pre Heating
ON/OFF
.com
is required.