R&S NGL-COM2A Getting Started page 23

Hide thumbs Also See for NGL-COM2A:
Table of Contents

Advertisement

®
R&S
NGL200/NGM200
Ethernet connector (13)
10/100 Ethernet port for remote control operation via the local area network.
For a detailed description on the connection setup, see section "LAN Connection"
in the User Manual.
Option IEEE-488 (GPIB) interface (14)
An IEEE-488 (GPIB) interface can be ordered (NGL-B105 or NGM-B105). This
interface is not user installable.
Digital I/O connector (15)
The Digital I/O option (R&S NGL-K103 or R&S NGM-K103) must be installed for
this function to be available in the instrument.
The specified voltages are 0 V to 24 V for all output pins and 0 V to 15 V for all
input pins.
Figure 4-3: Digital I/O connector (female socket front view)
Table 4-1: Digital I/O pin layout
Pin
Signal
1
*Inhibit Ch1
2
Trigger Ch1
3
In
4
Out1
5 - 8
Gnd
* The
inhibit signals
nal.
Getting Started 1178.8720.02 ─ 05
Direction
IN
IN
IN
OUT
-
can be used to turn off the outputs by a digital hardware sig-
Pin
Signal
9
*Inhibit Ch2
10
Trigger Ch2
11
Output Fault
12
Out2
13 - 15 Gnd
Instrument Tour
Overview of Controls
Direction
IN
IN
OUT
OUT
-