IHP Superior Fireplaces Custom BRT4036TMN-B Installation And Operation Instruction Manual

Decorative b-vent fireplaces millivolt system

Advertisement

Quick Links

P/N 900806-00 REV. A 08/2017
Ce manuel est disponible en francais, simplement en
faire la demande. Numéro de la pièce 900806-02.
P900806-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
Decorative Product: Not for use as a heating
appliance.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
Custom Series Decorative B-Vent Fireplaces
Millivolt System
Models
BRT4036TMN-B
BRT4336TMN-B
C
US
BRT4536TMN-B
Report No. F09-143
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
NOTICE: Fireplace is not to be operated by a
thermostat.
BRT4036TMP-B
BRT4336TMP-B
BRT4536TMP-B
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
BRT4042TMN-B
BRT4042TMP-B
BRT4342TMN-B
BRT4342TMP-B
BRT4542TMN-B
BRT4542TMP-B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Superior Fireplaces Custom BRT4036TMN-B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IHP Superior Fireplaces Custom BRT4036TMN-B

  • Page 1 Installation and Operation Instructions Custom Series Decorative B-Vent Fireplaces Millivolt System P/N 900806-00 REV. A 08/2017 Models Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 900806-02. BRT4036TMN-B BRT4036TMP-B BRT4042TMN-B BRT4042TMP-B BRT4336TMN-B BRT4336TMP-B BRT4342TMN-B BRT4342TMP-B BRT4536TMN-B BRT4536TMP-B...
  • Page 2: Table Of Contents

    Thank you for your purchase. We appreciate your TABLE OF CONTENTS business! Safety ..................... 3 Please carefully read and follow all instructions in this manual. Pay Unpacking ..................4 special attention to all warnings and safety information. Introduction ................... 5 Following these safety, care, and operation instructions will help Selecting Location ................
  • Page 3: Safety

    SAFETY Continued 3. If you smell gas WARNING: This product contains and/or generates • shut off gas supply chemicals known to the State of California to cause • do not try to light any appliance • Leave the building immediately. cancer or birth defects or other reproductive harm.
  • Page 4: Unpacking

    MAY CAUSE A FIRE HAZARD! absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/ The IHP warranty will be voided by and IHP disclaims any responsibil- NFPA 54—latest edition (In Canada, the current CAN/CGA-B149.1 ity for the following actions : installation code).
  • Page 5: Introduction

    INTRODUCTION Continued 2. Consider a location where heat output would not be affected by WARNING: Installation of this appliance should be drafts, air conditioning ducts, windows or doors. done by a qualified service person well trained in the 3. A location that avoids the cutting of joists or roof rafters will make installation of such appliances.
  • Page 6: Product Specifications

    PRODUCT SPECIFICATIONS GAS RATING - NATURAL BRT4036TMN-B, 4336TMN-B, 4536TMN-B BRT4042TMN-B, 4342TMN-B, 4542TMN-B Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 3.5" WC (.87 kPa) 3.5" WC (.87 kPa) Minimum Supply Pressure: 4.5" WC (1.12 kPa) 4.5" WC (1.12 kPa) Maximum Supply Pressure: 10.5"...
  • Page 7: Pre-Installation Preparation

    PRE-INSTALLATION PREPARATION MANTEL CLEARANCES AND WALL DETAILS CLEARANCES Minimum clearances to combustibles are: A combustible mantel shelf maybe installed a maximum 12" (22.9 cm) from the wall. Figures 5 and 6 show the minimum allowable distances Back and Sides of Outer Surround 0"...
  • Page 8 PRE-INSTALLATION PREPARATION Continued FRAMING These Dimensions Allow for a 3/4" Clearance at Sides and 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Back of Fireplace. However, 0" Clearance is Permitted. NOTE: If a wall covering is used to line the enclosure, then all mea- surements must be from the surface of the covering.
  • Page 9: Venting Installation

    VENTING INSTALLATION A B-type venting system must be connected to the appliance for IMPORTANT NOTICE venting to the outside of the building. The following section is provided as a guide to a standard B-type ANSI Z223.1/NFPA 54 (USA), or CSA B149.1 (Canada) vent installation.
  • Page 10 VENTING INSTALLATION Continued Some codes areas allow the use of existing B-type vent systems if CHECKING FOR PROPER VENTING the system is at or above the recommended diameter of the flue, in After completing and checking electrical, gas and vent connections, this case 6".
  • Page 11: Installation

    INSTALLATION WALL SWITCH INSTALLATION The installation of a wall switch allows you to activate the gas control valve without normal household electricity since valve operates on millivolt current supplied by heat generated by the thermopile. To install wall switch: 1. Remove front refractory access panel by lifting up and angling out of firebox opening (see Figure 13).
  • Page 12 In conformance with local codes, route a 1/2" NPT gas line to appliance IHP recommends that a black iron gas line be routed from the gas through hole in left side of firebox or sub-floor as shown in Figure 16.
  • Page 13 INSTALLATION Continued Complete your gas installation by connecting incoming gas line with flexible gas line. Secure tightly with wrench but DO NOT OVERTIGHTEN. EMBER AND PAN MATERIAL PLACEMENT 1. Open bag(s) of vermiculite and fill until it is even across burner pan (see Figure 19). 2.
  • Page 14 INSTALLATION Continued INSTALLATION Continued LOG PLACEMENT FOR BRT4036-B, BRT4336-B AND BRT4536-B Log 4 MODELS Log 3 1. Place small front right log (log 1) on right front of grate as shown in Figure 22. 2. Place large back log (log 2) onto grate making sure notches rest over grate as shown in Figure 22.
  • Page 15 INSTALLATION Continued LOG PLACEMENT FOR BRT4042, BRT4342 AND BRT4542 MODELS Log 3 1. Place large back log (log 1) onto grate making sure notches rest over grate (see Figure 26). Log 4 2. Insert lower end of log 2A between first two grate fingers and position upper end into notch on front of log 1.
  • Page 16 INSTALLATION Continued COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) INSTALLING OPTIONAL GLASS DOOR ACCESSORY The outside air kit may be installed on the left side of fireplace only. The vent can be installed through any outside wall a minimum of three CAUTION: Use only glass doors certified for use feet below fireplace termination cap.
  • Page 17 INSTALLATION Continued 6. Repeat the process for the opposite door assembly. Spring Clip Fold Bi-Fold Door 7. To adjust doors, slide them partially open. Using a screwdriver, After Releasing loosen hold-down screws in the spring clip (see Figure 33) and Spring Clip and pivot plate.
  • Page 18: Operation

    OPERATION 10. Push in knob all the way and hold in. Immediately light the pilot FOR YOUR SAFETY manually. Continue to hold control knob in for about one minute READ BEFORE LIGHTING after pilot is lit. Release knob and it will pop back up. Pilot should remain lit.
  • Page 19: Inspecting Pilot And Burner Flame Patterns

    INSPECTING PILOT AND BURNER FLAME PATTERNS CLEANING AND MAINTENANCE Periodically check pilot flame pattern and burner flame patterns often. WARNING: Installation and repair should be done PILOT ASSEMBLY by a qualified service person. The appliance should The pilot assembly is factory preset for the proper flame height. be inspected before each use and at least annually Alterations may have occurred during shipping and handling.
  • Page 20: Wiring Diagram

    WIRING DIAGRAM PILOT BURNER THERMOPILE REPLACE FACTORY WIRING WITH 105°C IGNITER EQUIVALENT OR HIGHER RATING EXTERNAL WIRING USE ONLY CLASS 2 THERMOSTAT WIRE 18 GA. RED/WHITE PILOT GAS LINE DO NOT CONNECT TO 120V WHITE N.O. SW N.C.SW MANUAL DAMPER TH/TP SWITCH INCOMING...
  • Page 21: Troubleshooting

    TROUBLESHOOTING NOTE: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging pilot and/or gas control valve filter OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Pilot will not light...
  • Page 22 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. •...
  • Page 23: Parts

    PARTS WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. MODEL CAT. NO. INTERIOR F3198 BRT4536TMN-B White Herringbone...
  • Page 24 PARTS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on Page 29 of this manual. KEY NO. CATALOG NO. DESCRIPTION 36" Models 42" Models QTY J6811 MICRO SWITCH • •...
  • Page 25 PARTS WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. BRT4036 BRT4336 BRT4536 NO. CATALOG NO. DESCRIPTION Black Interior...
  • Page 26 PARTS WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. LOG SETS FOR 36"MODELS LOG SETS FOR 42" MODELS...
  • Page 27: Accessories

    ACCESSORIES NOTICE: All accessories may not be available for all fireplace models. CAT NO. MODEL DESCRIPTION EXTRUDED ALUMINUM BI-FOLD GLASS DOORS F0981 BD36 36" Standard Bi-Fold Glass Door - Black finish F0982 BD36B 36" Standard Bi-Fold Glass Door - Brushed Brass finish F0983 BD36P 36"...
  • Page 28 ACCESSORIES Continued CAT NO. MODEL DESCRIPTION PERIMETER TRIM KIT F1042 PT36 36" Perimeter Trim Kit - Black F1043 PT36B 36" Perimeter Trim Kit - Brushed Brass F1044 PT36P 36" Perimeter Trim Kit - Platinum F1045 PT42 42" Perimeter Trim Kit - Black F1046 PT42B 42"...
  • Page 29: Service Hints

    • pilot will not stay lit Normally, all parts should be ordered through your IHP distributor • burner will have delayed ignition or dealer. Parts will be shipped at prevailing prices at time of order.
  • Page 30 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ SuperiorFireplaces.us.com 900806-00_A...
  • Page 31: Warranty

    In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike, Suite 108;...
  • Page 32 Type of gas fireplace uses Dealer name IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.

Table of Contents