■ Name of parts

(a)
(b)
(c)
(d)
(a) Touch panel display
• When the screen is touched or the On/Off button is
pressed while backlight is set to Enable, backlight
lights. Backlight goes off 30 or 60 seconds after the
last operation. When backlight is set to Disable, it does
not light.
• Lightly touch the touch panel with your finger tips. A
commercially available stylus pen can also be used.
If pushed with too much force or operated with a
rod, pencil, or ballpoint pen, etc., the display may be
scratched or damaged.
• Do not touch 2 or more places simultaneously. Correct
operation cannot be performed.
• When cleaning, do not use detergent or alcohol, paint
thinner, etc. It will cause accidents or loss of appear-
ance.
(b) LED lamp (Power indicator)
Lights while the indoor unit is operating. Blinks when an
error is generated.
(c) On/Off button
(d) Room temperature sensor (inside)

1 MONITOR

1-1 Monitor

1-1-1 Monitor mode screen

Monitor mode screen is the home screen of this unit.
(a)
(d)
Office
Mode
Set Temp.
26.0
26.0
(i)
Cool
(c)
(i)
(a) R.C. group name:
Name of the remote controller group to which this unit is
connected.
(b) Clock
(c) Mode:
When this is touched, the display switches to the "Mode"
(i)
(b)
Fri 10:00AM
Fan
(e)
Auto
°C °C
26.0°C
26.0°C
(f)
Room Temp.
Status
Menu
(h)
(g)
screen. Refer to [2 CONTROL] → [2-2 Operation Set-
tings] → [2-2-1 Set the Operation Mode].
When the operation mode
is set to [Custom Auto], the
set temperature is displayed
for cooling and heating.
(d) Set temp.:
When this is touched, the display switches to the tem-
perature setting screen. Refer to [2 CONTROL] → [2-2
Operation Settings] → [2-2-2 Set the Temperature].
(e) Fan:
When this is touched, the display switches to the fan
speed setting screen. Refer to [2 CONTROL] → [2-2
Operation Settings] → [2-2-3 Set the Fan Speed].
(f)
Room temp.:
The ambient temperature sensed by this unit is dis-
played.
(g) Menu:
When this is touched, the display switches to the "Menu"
screen. Refer to [3 SETTING].
(h) Status (for administrator)
(i)
Status icons:
An error occurred. (for administrator)
Operation from this unit is prohibited by the Cen-
tral Controller. (for administrator)
Mode mismatch. The mode which cannot operate
simultaneously is selected. (for administrator)
The On Timer, Off Timer, or Auto Off Timer is set.
Refer to [3 SETTING] → [3-4 Timer Setting].
The weekly timer is set. (for administrator)
The set temperature automatic return setting is
set. (for administrator)
It shows that it is time to clean the filter. (for admin-
istrator)
The temperature sensor of this unit is used. (for
administrator)
For the screen display, this product uses a Bitmap font made
and developed by Ricoh Company, Ltd.
During the Lead lag operation, the monitor mode display dif-
fers as below.
(a) R.C. group name:
"Lead Lag" is shown.
(c) Mode:
You cannot change the operation mode during the Lead
lag operation. The screen does not move even if you
touch here.
(g) Menu:
When touching, the display switches to the "Lead Lag
Setting" screen (for administrator).
(h) Status:
It does not appear.
(i)
Status icons:
lights if an error has occurred.
blinks during the Lag operation.
Set Temp.
28.0°C
28.0°C
Cool
20.0°C
20.0°C
Heat
En-2