■ NAME OF PARTS

(a)
(b)
(c)
(d)
(a) Touch panel display
• When the screen is touched or the On/Off button is
pressed while backlight is set to Enable, backlight
lights. Backlight goes off 30 or 60 seconds after the
last operation. When backlight is set to Disable, it does
not light.
• Lightly touch the touch panel with your fi nger tips. A
commercially available stylus pen can also be used.
If pushed with too much force or operated with a
rod, pencil, or ballpoint pen, etc., the display may be
scratched or damaged.
• Do not touch 2 or more places simultaneously. Correct
operation cannot be performed.
• When cleaning, do not use detergent or alcohol, paint
thinner, etc. It will cause accidents or loss of appear-
ance.
(b) LED lamp (Power Indicator)
Lights while the indoor unit is operating. Blinks when an
error is generated.
(c) On/Off button
(d) Room temperature sensor (Inside)

1 MONITOR

1-1 Monitor

1-1-1 Monitor Mode Screen

Monitor Mode Screen is home screen of this unit.
(a)
(d)
Office
Mode
Set Temp.
(i)
26.0
26.0
Cool
(c)
(i)
(a) R.C. group name:
Name of the remote controller group to which this unit is
connected.
(b) Clock:
(c) Mode:
When this is touched, the display switches to the "Mode"
screen. Refer to [2 CONTROL] → [2-2 Operation Set-
tings] → [2-2-1 Set the Operation Mode].
(d) Set temp.:
When this is touched, the display switches to the tem-
perature setting screen. Refer to [2 CONTROL] → [2-2
Operation Settings] → [2-2-2 Set the Temperature].
(e) Fan:
When this is touched, the display switches the fan speed
setting screen. Refer to [2 CONTROL] → [2-2 Operation
Settings] → [2-2-3 Set the Fan Speed].
(f)
Room Temp.:
This unit ambient temperature sensed by this unit is
displayed.
(g) Menu:
When this is touched, the display switches to the "Menu"
screen. Refer to [3 SETTING].
(h) Status: (for manager)
(i)
Status icons:
The error occurred. (for manager)
Operation from this unit is prohibited by the Central
Controller. (for manager).
Mode mismatch. The mode which cannot operate
simultaneously is selected. (for manager)
The On Timer, Off Timer, or Auto Off Timer is set.
Refer to [3 SETTING] → [3-3 Timer Setting].
The weekly timer is set. (for manager)
The set temperature automatic return setting is set.
(for manager)
It shows that it is time to clean the fi lter. (for man-
ager)
The temperature sensor of this unit is used. (for
manager)
This product uses a Bitmap font made and developed by
Ricoh Co.,Ltd.
(i)
(b)
Fri 10:00AM
Fan
(e)
Auto
°C °C
(f)
26.0°C
26.0°C
Room Temp.
Status
Menu
(h)
(g)
En-2