18: Advanced Parameters - FIBARO FGTSP-001 Operating Manual

Radiator thermostat
Table of Contents

Advertisement

#18: Advanced parameters

The device allows to customize its operation to user's needs. The set-
tings are available in the FIBARO interface as simple options that may
be chosen by selecting the appropriate box.
In order to configure the device (using the FIBARO Home Center con-
troller):
1. Go to the device options by clicking the icon:
2. Select the „Advanced" tab.
3. Modify values of chosen parameters.
4. Save the changes.
GENERAL SETTINGS
1. Override Schedule duration
This parameter determines duration of Override Schedule after turn-
ing the knob while normal schedule is active (set by Schedule CC).
Available settings: 10-10 000 (in minutes)
Default setting:
2. Additional functions
This parameter allows to enable different additional functions of the
device.
Available settings: 1 (bit 0) - enable Open Window Detector
Default setting:
3. Additional functions status (READ-ONLY)
This parameter allows to check statuses of different additional functions.
Available settings: 1 (bit 0) - optional temperature sensor connect-
Default setting:
240 (4h)
Parameter size:
2 (bit 1) - enable fast Open Window Detector
4 (bit 2) - increase receiver sensitivity (shortens
battery life)
8 (bit 3) - enabled LED indications when con-
trolling remotely
16 (bit 4) - protect from setting Full ON and Full
OFF mode by turning the knob manually
1
Parameter size:
ed and operational
2 (bit 1) - open window detected
0
Parameter size:
4 [bytes]
4 [bytes]
4 [bytes]
ADVANCED PARAMETERS
23
i
NOTE
Entering invalid value
of parameter will re-
sult in not setting the
value and response
with Application Re-
jected or Supervision
CC frame (depending
on the controller).
i
NOTE
Parameter 2 values
may be combined,
e.g.
1+8=9
means
that Open Window
Detector and LED in-
dications when con-
trolling remotely are
enabled.
i
NOTE
Parameter 3 values
may be combined, e.g.
1+2=3 means optional
sensor works properly
and open window de-
tection was triggered.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fgt-001

Table of Contents