18
OVERRIDE SCHEDULE

#16: Override Schedule

Override Schedule is a special type schedule that has the highest
priority; thus it overrides other schedules.
The Override Schedule starts right after setting and lasts for specified
time, then it is removed and current schedule or normal operation is
restored.
To create Override Schedule user must specify:
Starting time (START NOW),
Duration,
Temperature Setpoint for HEAT mode in range 10-30°C (using
Thermostat Setpoint CC)
One of the operating modes (using Thermostat Mode CC):
» HEAT for setting temperature,
» OFF for valve fully closed,
» MANUFACTURER SPECIFIC for valve fully opened.
Override Mode can be enabled in two ways:
By turning the knob, while normal schedule is active. The LED ring
will pulse with selected adjustment.
Via controller, by creating schedule with ID set 255, start time set
to NOW and duration (in minutes/hours/days).
To exit Override Mode grab knob with your hand for 5 seconds.