OFF
AUX MAV
SET
EJEJEJ [!7
RECLAIM START
30:00
SET
EJEJEJ [!7
RECLAIM DURATION
6:00
SET
EJEJEJ [!7
Brine Reclaim: When Reclaim is selected as trigger for Auxilliary MAV Drive, a portion of the brine can be diverted after it has passed through
the resin bed. Brine discharge contains unused salt that can be used for brine make-up for the next regeneration. A motorized alternator valve
(MAV) must be connected to the two-pin connector labeled AUX 1 located on the circuit board or error code 106 will result. The MAV diverts
the brine discharge to brine tank. A-Port discharges to brine tank. B-Port discharges to drain, remaining port connects to the valve drain fitting.
For start time and duration settings an elution study must be done to provide settings that optimize salt savings without sacrificing capacity.
21
STEP 4CS – Use the  or  buttons to select one of the following:
STEP 4CS
• Reclaim – Allows brine reclaimation. Select Reclaim for 1 Reclaim Event, Reclaim 2x for
2 reclaim events and Reclaim 3x for 3 reclaim events.
[!J
• Separate Source –Allows Auxiliary MAV to switch positions before the start of regenera-
tion and to switch back at the end of regeneration.
• Off - Factory Setting is Off
Press NEXT to go to next step when reclaim selected as trigger. Press REGEN to return
to previous step.
Only displays if reclamation of brine is enabled. Use the  or  buttons to select the
MIN
number of minutes after the start of regeneration before the MAV will divert the brine waste
water from the plumbing drain receptacle to the brine tank. Start of regeneration is defined
[!J
as any mode that is not fill or softening.
Press NEXT to go to next step. Press REGEN to return to previous step.
Only displays if reclamation of brine is enabled. Use the  or  buttons to select
MIN
the number of minutes to divert the brine waste water to the brine tank. After the minutes
count down to zero the waste water will once again be diverted to the plumbing drain
[!J
receptacle.
Press NEXT to go to next step.. Press REGEN to return to previous step.