LOCATION

The appliance shall be installed in accordance with national wiring regulations. Improper
connection may cause the power cord, and the electrical outlet to overheat and fire.
Install the air conditioner to the opening dimensions shown below.
Never install the unit where any of the air inlet is blocked.
The air conditioner should be installed with a strong external support to minimize noise and
vibration, and for the purpose of safe installation, repair, replacement and secure positioning.
Avoid installing the air conditioner where it is exposed to direct sunlight.
More than 40cm(16")
More than 20cm(8")
Air inlet

POWER CABLING

GROUNDING
WARNING: THIS APPLIANCE MUST BE GROUNDED.
Fit a disconnect switch, having a contact separation of at
least 3mm in all poles, to the electricity power line.
Connect the brown wire of the power supply cord to the live
terminal, and the grounding wire (green and yellow) to the
grounding terminal of the electrical outlet. The remaining
wire should be connected to the neutral terminal of the
electrical outlet.
FUSE
For safe, trouble free operation, connect the power cord
of the unit to a properly rated independent circuit with a
time delay fuse or a circuit breaker. See chart for proper
amp ratings for each model.
AF-W18CME
Downloaded from:
http://www.usersmanualguide.com/
43.5~44.5 cm
(17 1/8"~17 1/2")
More than 20 cm
(8")
More than 20cm(8")
Air outlet
Air inlet
Air inlet
20 amp.
More than 20 cm(8")
8 c m
6 7 ~ 6
" )
6 3 / 4
/ 8 " ~ 2
( 2 6 3
8~20 cm(3"~8")
Air inlet
Air outlet
15
More than 40cm
(16")
About 1cm
(3/8")
Grounding wire
Neutral
(green&yellow)
(blue)
Live
(brown)
Maximum Permissible
System Impedance
0.13
( AF-W18CME)