Ventilation For Built-In Installations - Viking CVGBQ53024 Installation Manual

Outdoor gas grills
Hide thumbs Also See for CVGBQ53024:
Table of Contents

Advertisement

Ventilation for Built-In Installations

An enclosure for an LP-gas cylinder shall be ventilated by openings at both the upper and lower levels of
the enclosure. The effectiveness of the opening(s) for purposes of ventilation shall be determined with the
LP-gas supply cylinder in place. This shall be accompanied by one of the following:
a.
One side of the enclosure shall be completely open; or
b.
For an enclosure having four sides, a top and a bottom:
1. At least two ventilation openings (See Part IV, Definitions) shall be provided in the side walls of the
enclosure, located within 5 in. (217 mm) of the top of the enclosure, equally sized, spaced at a
minimum of 90 degrees (1.57 rad), and unobstructed. The opening(s) shall have a total free area of not
less than 1 in2/lb (1.42 cm2/kg) of stored fuel capacity.
2. Ventilation opening(s) shall be provided at floor level at rear of the enclosure and shall have a total free
area of not less than 1/2 in2/lb (7.1 cm2/kg) of stored fuel capacity. The bottom of the openings shall
be 1 in. (25.4 mm) or less from the floor level and the upper edge no more
the floor level. The openings shall be equally sized, spaced at a minimum of 90 degrees (1.57 rad) and
unobstructed.
3. Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 inch (3.2 mm)
diameter rod.
4. Ventilation openings in the side walls shall not communicate directly with other enclosures of the
outdoor cooking gas appliance.
Note: It is strongly recommended to follow the same ventilation requirements when using Natural Gas.
Vents
Vents
5.00
5.00 inch
inch
maximum
maximum
All vents no more than
All vents no more
than 5.00
5.00 inches
inches
above the floor of the installation.
above the floor of the installation.
Vents located
Vents located
on sidewall
on sidewall
16
Not
Not more
more than 5.00
than 5.00
inches from inside
inches from inside
bottom of countertop.
bottom of countertop.
5.00
5.00 inch
inch
maximum
maximum
1.00
1.00 inch
inch maximum
maximum
Bottom Vent not
Bottom Vent not
more
more than 1.00 inch
than 1.00 inch
from inside floor of
from inside floor of
installation.
installation.
than 5 in. (127 mm) above