PROJECTOR SETUP menu
4 ) Press <ENTER> button.
The [ADJUST CLOCK] screen will be displayed.
z
5 ) Press ▲▼ to select the item to be set,
and press ◄► to set the local time.
6 ) Press ▲▼ to select [APPLY], and
press <ENTER> button.
This completes setting of the time.
z
Adjusting the date and time
J
automatically
1 ) Press ▲▼ to select [DATE AND TIME].
2 ) Press <ENTER> button.
3 ) Press ▲▼ to select [ADJUST CLOCK].
4 ) Press <ENTER> button.
The [ADJUST CLOCK] screen will be displayed.
z
5 ) Press ▲▼ to select [NTP
SYNCHRONIZATION] and press ◄► to
switch to [ON].
The setting will change as follows each time
z
◄► is pressed.
OFF
6 ) Press ▲▼ to select [APPLY], and
press <ENTER> button.
This completes setting of the time.
z
Note
z To set the date and time automatically, the projector must
be connected to the network.
z If synchronization with the NTP server fails just after
[NTP SYNCHRONIZATION] is turned [ON], or if [NTP
SYNCHRONIZATION] is turned [ON] while the NTP
server is not set, [NTP SYNCHRONIZATION] will return
to [OFF].
z Access the projector via a web browser to set the NTP
Æ
server. (
page 107)
86
- ENGLISH

LENS CALIBRATION

This automatically sets the limit value of the lens shift
and the home position of the projector.
1 ) Press ▲▼ to select [LENS
CALIBRATION].
2 ) Press <ENTER> button.
A confirmation message will be displayed.
z
3 ) Press ◄► to select [OK], and press
<ENTER> button.
To stop, select [CANCEL].
z
The lens will move vertically and horizontally,
z
and the limit value of the lens shift and home
position are set automatically.
The lens will stop, completing the calibration.
z
Note
z While lens calibration is being executed, a message
[PROGRESS] appears on the menu. The calibration
cannot be canceled halfway.
z If the lens calibration has been correctly executed, a
message [COMPLETE] will appear. If the calibration has
not been correctly executed, a message [INCOMPLETE]
will appear.
ON

FILTER COUNTER RESET

After you replaced the Auto Cleaning Filter (ACF),
[REMAINING FILTER] of [STATUS] need to be reset
to [0].
1 ) Press ▲▼ to select [FILTER COUNTER
RESET].
2 ) Press <ENTER> button.
The [RESET FILTER COUNTER?] screen will
z
be displayed.
3 ) Press ◄► to select [OK], and press
<ENTER> button.
Note
z For replacing ACF unit, refer to "
replacement" (
z If the filter has not been installed, [OK] cannot be
selected.
z The filter is wound during the resetting operation. Some
sound may be produced during the winding operation.
Procedure of ACF unit
Æ
page 110).