Motorola RFS4011 Series Installation Manual page 11

Integrated services controller
Table of Contents

Advertisement

RFS4000_Baseline.book Page 7 Tuesday, September 28, 2010 9:55 AM
3.1.4 Fan LED
Fan LED
Off
Green Blinking
Green Solid
Amber Solid
Amber Blinking
3.1.5
Temperature Status LED
Temperature LED
Off
Green Solid
Amber Solid
Amber Blinking
Event
System Off / POST Start
POST in Process
All System Fans Normal Operation
Redundant Cooling Failure
System Operational
System Cooling Failure
System will be held in reset until the issue is
resolved
Event
System Off
Ambient Inlet Temperature is within specified
operating limit
Ambient Inlet Temperature is near the maximum
operating temperature
During controller start up, this LED will be lit
Solid Amber. This is normal behavior and does
not indicate an error.
Ambient Inlet Temperature is above the
maximum specified operating temperature
System will be held in reset until the issue is
resolved