Contacting Supermicro; System Notes; Nodes; System Power - Supermicro SuperStorageSystem SSG-2028R-DN2R40L User Manual

Table of Contents

Advertisement

SUPERSTORAGESYSTEM SSG-2028R-DN2R40L User's Manual
1-5

Contacting Supermicro

Headquarters
Address:
Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel:
+1 (408) 503-8000
Fax:
+1 (408) 503-8008
Email:
marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Website:
www.supermicro.com
Europe
Address:
Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel:
+31 (0) 73-6400390
Fax:
+31 (0) 73-6416525
Email:
sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Website:
www.supermicro.nl
Asia-Pacific
Address:
Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C)
Tel:
+886-(2) 8226-3990
Fax:
+886-(2) 8226-3992
Email:
support@supermicro.com.tw
Website:
www.supermicro.com.tw
1-6
1-6

System Notes

The SSG-2028R-DN2R40L Super SBB was designed to function as a fully
redundant, fault-tolerant "cluster-in-a-box" system with hot-swappable nodes for all
active components.

Nodes

The SSG-2028R-DN2R40L features a dedicated B2B connection using an Intel
XL710 private LAN connecting the bottom server module with the top server
module. This connection is used for high speed data transfers between nodes for
High Availability/server fail-over. This fail-over capability is fully dependent on the
software/OS installed and how the chosen software uses the connection (Active-
Active or Active-Passive). The SSG-2028R-DN2R40L hardware is supplied without
a storage OS or fail-over software.
Equipped with 2000 Watt 80+ Titanium Level redundant power supplies and
redundant cooling fans, the SSG-2028R-DN2R40L offers fully redundant, high
availability while maintaining energy efficient operation.
Note: A guide pin is located between the upper and lower nodes on the inner chassis
wall. This guide pin also acts as a "stop" when a node is fully installed.

System Power

Dual 2000 Watt power supplies are used to provide the power for all serverboards.
Each serverboard however, can be shut down independently of the other with the
power button on its own control panel.

NVMe Backplane/Drives

As a system, the SuperStorageSystem SSG-2028R-DN2R40L supports the use of
forty (40) 2.5" NVMe drives. The NVMe backplane works to apply system-based
control for power and fan speed functions. See the Drive Bay Installation/Removal
section in Chapter 6 for the logical hard drive and node configuration.
Chapter 1: Introduction
1-7

Advertisement

Table of Contents
loading

Table of Contents