Vivotek SUPREME use IP FE9582-EHNV User Manual page 304

Fisheye network camera
Table of Contents

Advertisement

VIVOTEK
databit
paritybit
stopbit
uartmode
customdrvcmd_i<0~9>
speedlink_i<0~4>_name
speedlink_i<0~4>_cmd
ptzdriver
7.42 UART control (SD series)
Group: uart_i<0~(n-1)> n is uart port count
bit4 of capability_ptzenabled is 1)
NAME
cameraid
baudrate
304 - User's Manual
2400,3600,4800,72
00,9600,19200,384
00,57600,115200
5,6,7,8
4/4
none,
4/4
odd,
even
1,2
4/4
rs485,
4/4
rs232
string[128]
1/4
string[40]
1/4
string[40]
1/4
0~19,
1/4
127 (custom),
128 (no driver)
(capability.nuart > 0 and the bit7 of capability_ptzenabled is 0, the
VALUE
SECURITY
(get/set)
1~255
4/4
2400,4800,9600,19
4/4
200,38400,57600,1
15200
Data bits in a character frame.
For error checking.
1
2-1.5 , data bit is 5
2-2
RS485 or RS232.
PTZ command for custom camera.
Additional PTZ command name.
Additional PTZ command list.
The PTZ driver is used by this COM port.
DESCRIPTION
Camera ID controlling external PTZ camera.
Note:
Please set your speed dome to the appropriate
baud rate, and Camera ID, e.g. 2400bps,
camera ID 1,2,3,,,,etc.
All Camera IDs on the same controlling system
(NVR or rs485 keyboard) have to be distinct.
Therefore, once you send a controlling signal,
each camera will only accept the inputs with
the corresponding ID.
Set baud rate of COM port.