Field settings table
Breadcrumb
Field code
Setting name
9.I
[C-05]
What is the thermo request contact type for the main zone?
9.I
[C-06]
What is the thermo request contact type for the add. zone?
9.I
[C-07]
What is the unit control method in space operation?
9.I
[C-08]
Which type of external sensor is installed?
9.I
[C-09]
What is the required alarm output contact type?
9.I
[C-0A]
--
9.I
[C-0B]
--
9.I
[C-0C]
--
9.I
[C-0D]
--
9.I
[C-0E]
--
9.I
[D-00]
Which heaters are permitted if prefer. kWh rate PS is cut?
9.I
[D-01]
Contact type of preferential kWh rate PS installation?
9.I
[D-02]
Which type of DHW pump is installed?
9.I
[D-03]
Leaving water temperature compensation around 0°C.
9.I
[D-04]
Is a demand PCB connected?
9.I
[D-05]
Is the pump allowed to run if prefer. kWh rate PS is cut?
9.I
[D-07]
Is a solar kit connected?
9.I
[D-08]
Is an external kWh meter used for power measurement?
9.I
[D-09]
Is an external kWh meter used for power measurement?
9.I
[D-0A]
--
9.I
[D-0B]
--
9.I
[D-0C]
--
9.I
[D-0D]
--
9.I
[D-0E]
--
9.I
[E-00]
Which type of unit is installed?
9.I
[E-01]
Which type of compressor is installed?
9.I
[E-02]
What is the indoor unit software type?
9.I
[E-03]
What is the number of backup heater steps?
9.I
[E-04]
Is the power saving function available on the outdoor unit?
9.I
[E-05]
Can the system prepare domestic hot water?
9.I
[E-06]
Is a DHW tank installed in the system?
9.I
[E-07]
What kind of DHW tank is installed?
9.I
[E-08]
Power saving function for outdoor unit.
9.I
[E-09]
--
9.I
[E-0A]
--
9.I
[E-0B]
Is a bi-zone kit installed?
9.I
[E-0C]
--
9.I
[E-0D]
Is glycol present in the system?
9.I
[E-0E]
--
9.I
[F-00]
Pump operation allowed outside range.
9.I
[F-01]
--
9.I
[F-02]
Bottom plate heater ON temperature.
9.I
[F-03]
Bottom plate heater hysteresis.
9.I
[F-04]
Is a bottom plate heater connected?
9.I
[F-05]
--
9.I
[F-09]
Pump operation during flow abnormality.
9.I
[F-0A]
--
9.I
[F-0B]
Close shut-off valve during thermo OFF?
9.I
[F-0C]
--
(*1) *3V_
(*2) *6V_
(*3) *9W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/O
R/W
R/W
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/O
R/W
R/O
R/W
R/W
R/W
R/W
R/W
R/W
(#) Setting is not applicable for this unit.
Range, step
Default value
0: -
1: 1 contact
2: 2 contacts
0: -
1: 1 contact
2: 2 contacts
0: LWT control
1: Ext RT control
2: RT control
0: No
1: Outdoor sensor
2: Room sensor
0: Normally open
1: Normally closed
0
0
0
0
0
0: None
1: BSH only
2: BUH only
3: All heaters
0: No
1: Active open
2: Active closed
3: Smart grid
0: No
1: Secondary rtrn
2: Disinf. Shunt
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
0: No
1: Pwr consmp ctrl
0: Forced off
1: As normal
0: No
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
8: 1 pulse/m³ (gas meter)
9: 10 pulses/m³ (gas meter)
10: 100 pulses/m³ (gas meter)
0
2
0
0
0
0~5
0: LT split
0
1: Heating only
2: 3V (*1)
3: 6V (*2)
4: 9W (*3)
0: No
1: Yes
0: No
1: Yes
0: No
1: Yes
1: Integrated
0: Disabled
1: Enabled
1
0
1: Yes
0
0
0
0: Disabled
1: Enabled
20
3~10°C, step: 1°C
3°C
2~5°C, step: 1°C
5°C
0: No
1: Yes
0
0: Disabled
1: Enabled
0
0: No
1: Yes
1
9/10
Installer setting at variance with
default value
Date
Value
4P629095-1A - 2021.02