Models
Digital Radiant Cooktop
Available
Dimensions
& Clearances
20-1/2"
2-3/4"
19-1/4"
Max.
This cooktop has a control system that is fan
Advance
cooled during heavy usage conditions. This
Planning
requires a minimum of 15" free-space below
the cooktop bottom to an internal enclosure;
such as a full depth cabinet shelf; to provide
this air circulation.
– Do not block vents on the underside and at
– Do not block exhaust fan outlet located on
See "Base Cabinet Heat Clearances" for fan
and vent locations.
• Use this cooktop with any exhaust hood;
• Refer to "Dimensions and Clearances" for
• Avoid placing cabinetry directly above the
30"
28-3/8"
the right front and right sides.
the bottom of the cooktop.
no special overhead ventilation is required.
appropriate placement and clearances when
planning installation.
cooktop when possible.
Design Information
Digital Radiant Cooktop
This Monogram cooktop offer a smooth
glass surface with bridgeburner to form an
elongated heating area. A beveled glass edge
provides a trimless appearance.
• The underside (recessed) dimensions are:
– 28-1/8" wide (including spacers),
– 3-5/8" high,
– 19" front to back (including spacers).
3-3/4"
1-1/2" Min.
2" Min.
Required
• If cabinetry is used above the cooking
surface:
–Use cabinets no more than 13" deep.
– Maintain 30" minimum clearance between
cooktop and unprotected cabinets directly
above cooktop.
– Maintain 24" minimum clearance when
bottom of wood or metal cabinet is pro-
tected by not less than 1/4" thick flame-
retardant millboard covered with not less
than no. 28 MSG sheet steel, 0.015 inch
thick stainless steel, 0.024 inch thick
aluminum, or 0.020 inch thick copper.
– A 30" wide exhaust hood that projects at
least 5" beyond the front of the upper
cabinets can also reduce risks.
• Working areas adjacent to the cooktop
should have 18" minimum clearance
between countertop and cabinet bottom.