Installation Preparation; Tools & Materials Required; Electrical Location; Base Cabinet Heat Clearances - GE Monogram ZEU304 Installation Instructions Manual

30" digital radiant cooktop
Table of Contents

Advertisement

• Drill and appropriate bits
Tools &
• Electric or hand drill
Materials
• Pencil
• Ruler
Required
• Carpenters square
• Hand or saber saw
Electrical
Location
This cooktop operates on 240 or 208 volts,
60 Hz, power supply and requires an indi-
vidual, properly-grounded branch circuit,
protected by 40 amp fuse or circuit breaker.
Install the junction box within reach of the
power cable:
– On the rear wall of the cabinet opening.
– At least 16" below the countertop.
IMPORTANT:
Base
Control Housing Air Flow Provision
Cabinet
The control system is fan cooled during usage.
Heat
Installation into a cabinet must not block the
Clearances
cooling air flow. Review illustrations carefully
before cutting the countertop to insure that
adequate space for the cooktop and clearances
for air space is available.
• Standoffs are positioned along the sides of
DO NOT ATTEMPT TO REMOVE THE
STANDOFFS.
• Flat-blade screwdriver
• Wire strippers
• 120/240 volt or 120/208 volt junction box.
• Electrical cable, 3-conductor or 4 conductor wire, as required
by local codes.
Note:
cord with this appliance.
WARNING
Warning, for
Personal Safety:
Remove house fuse or
open circuit breaker before
beginning installation.
Do not use an extension
cord or adapter plug with
this appliance. Follow National electrical
codes or prevailing local codes and
ordinances.
the cooktop. These standoffs provide a 1/4"
air gap between the countertop/cabinet and
the cooktop chassis.

Installation Preparation

Do not use an extension
• Connect house wiring to junction box in
accordance with local codes.
• Power is located on the bottom at the
center rear.
WARNING
appliance is properly grounded.
Standoffs
• Maintain 15" min. clearance below cooktop
bottom to any horizontal surface such as a
full depth cabinet shelf.
Digital Radiant Cooktop
Warning: The improper
connection of the equip-
ment-grounding conductor
can result in a risk of
electric shock. Check with a
qualified electrician or
service representative if you
are in doubt whether the
Air
Outlet
Air Intake
Air Intake