Swing gate operator swing gate operator (-68 board)
Table of Contents

Advertisement

A continuous FIRE input in either gate opens both gates and holds them open.
A continuous Manual STOP in either gate stops both gates.
There are 2 different ways to close the gate after entering or exiting:
1. Reclose Timer: When the Reclose Timer expires, the gates close automatically (Master or Slave).
2. ATG and Interrupt Loop: When ATG is ON, clearing the Inside Interrupt Loop causes the gate to
close (Slave unit only).
INPUT CONNECTIONS: (for more details, refer to Part 2, Paragraph L, Connecting Input Wiring)
SLIDE
Gate
ACTION
Type
Unit
Tandem
Option
Unit
Tandem
Option
:
Master and Slave units can have different settings.
:
Exit, Radio, Cycle, Fire, and Manual Stop inputs affect both gate operators, so connect inputs to one unit only.
32 of 53
MASTER UNIT SWITCH S1 SETTINGS AND INPUTS
(Reclose)
RETRY
TIMER
Unit
Unit
Option
Option
SLAVE UNIT SWITCH S1 SETTINGS AND INPUTS
Unit